Development of a flow rate monitoring method for the wearable ventricular assist device driver.

Kentaro Ohnuma1, Akihiko Homma, Hirohito Sumikura, Tomonori Tsukiya, Yoshiaki Takewa, Toshihide Mizuno, Hiroshi Mukaibayashi, Koichi Kojima, Kazuo Katano, Yoshiyuki Taenaka, Eisuke Tatsumi.   

Abstract

Our research institute has been working on the development of a compact wearable drive unit for an extracorporeal ventricular assist device (VAD) with a pneumatically driven pump. A method for checking the pump blood flow on the side of the drive unit without modifying the existing blood pump and impairing the portability of it will be useful. In this study, to calculate the pump flow rate indirectly from measuring the flow rate of the driving air of the VAD air chamber, we conducted experiments using a mock circuit to investigate the correlation between the air flow rate and the pump flow rate as well as its accuracy and error factors. The pump flow rate was measured using an ultrasonic flow meter at the inflow and outflow tube, and the air flow was measured using a thermal mass flow meter at the driveline. Similarity in the instantaneous waveform was confirmed between the air flow rate in the driveline and the pump flow rate. Some limitations of this technique were indicated by consideration of the error factors. A significant correlation was found between the average pump flow rate in the ejecting direction and the average air flow rate in the ejecting direction (R2 = 0.704-0.856), and the air flow rate in the filling direction (R2 = 0.947-0.971). It was demonstrated that the average pump flow rate was estimated exactly in a wide range of drive conditions using the air flow of the filling phase.

Mesh:

Year:  2014        PMID: 25500948     DOI: 10.1007/s10047-014-0811-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

Review 1.  Mechanical circulatory support for advanced heart failure: patients and technology in evolution.

Authors:  Garrick C Stewart; Michael M Givertz
Journal:  Circulation       Date:  2012-03-13       Impact factor: 29.690

2.  The Fourth INTERMACS Annual Report: 4,000 implants and counting.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2012-02       Impact factor: 10.247

Review 3.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

4.  Development of a compact portable driver for a pneumatic ventricular assist device.

Authors:  Tomohiro Nishinaka; Yoshiyuki Taenaka; Eisuke Tatsumi; Hiroyuki Ohnishi; Akihiko Homma; Kyoko Shioya; Toshihide Mizuno; Tomonori Tsukiya; Sadahiko Mushika; Yasuhiro Hashiguchi; Akira Suzuki; Soichiro Kitamura
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731

5.  Novel method to determine instantaneous blood volume in pulsatile blood pump using electrical impedance.

Authors:  E Sasaki; T Nakatani; Y Taenaka; H Takano; H Hirose
Journal:  Artif Organs       Date:  1994-08       Impact factor: 3.094

6.  Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.

Authors:  Mark S Slaughter; Francis D Pagani; Joseph G Rogers; Leslie W Miller; Benjamin Sun; Stuart D Russell; Randall C Starling; Leway Chen; Andrew J Boyle; Suzanne Chillcott; Robert M Adamson; Margaret S Blood; Margarita T Camacho; Katherine A Idrissi; Michael Petty; Michael Sobieski; Susan Wright; Timothy J Myers; David J Farrar
Journal:  J Heart Lung Transplant       Date:  2010-02-24       Impact factor: 10.247

7.  Age and preoperative total bilirubin level can stratify prognosis after extracorporeal pulsatile left ventricular assist device implantation.

Authors:  Taro Shiga; Koichiro Kinugawa; Masaru Hatano; Atsushi Yao; Takashi Nishimura; Miyoko Endo; Naoko Kato; Yasunobu Hirata; Shunei Kyo; Minoru Ono; Ryozo Nagai
Journal:  Circ J       Date:  2010-11-23       Impact factor: 2.993

8.  Multi-institutional studies of the National Cardiovascular Center Ventricular Assist System: use in 92 patients.

Authors:  H Takano; Y Taenaka; H Noda; M Kinoshita; A Yagura; E Tatsumi; H Sekii; E Sasaki; M Umezu; T Nakatani
Journal:  ASAIO Trans       Date:  1989 Jul-Sep

Review 9.  New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device.

Authors:  Shunei Kyo; Taishi Minami; Takashi Nishimura; Satoshi Gojo; Minoru Ono
Journal:  J Cardiol       Date:  2012-02-10       Impact factor: 3.159

10.  Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; J T Baldwin; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2013-02       Impact factor: 10.247

View more
  2 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2015: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; K Matsuda; E Tatsumi; G Matsumiya; T Tsukiya; T Abe; K Fukunaga; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2016-02-20       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.