A motion artifact generation and assessment system for the rapid testing of surface biopotential electrodes.

Alper Cömert1, Jari Hyttinen.   

Abstract

Dry electrodes can reduce cost while increasing the usability and comfort of wearable monitoring systems. They are, however, susceptible to motion artifacts. The present electrode testing methods lack reliability and do not separate the factors that affect the motion artifact. In this paper, we introduce a first generation motion artifact generation and assessment system that generates the speed, amplitude, and pattern-wise programmable movement of the electrode. The system simultaneously measures electrode-skin impedance, the motion artifact, and one channel of an electrocardiogram that contains the motion artifact and monitors the mounting force applied to the electrode. We demonstrate the system by comparing the applied movement and the measured signals for electrode movements up to 6 mm and movement frequencies from 0.4 Hz to 4 Hz. Results show that the impedance change and surface potential are visually clearly related to the applied motion, with average correlations of 0.89 and 0.64, respectively. The applied force, electrode location, and electrode structure all affect the motion artifact. The setup enables the motion of the electrode to be accurately controlled. The system can be used as a precursor to the testing of integrated systems because it enables thorough, repeatable, and robust motion artifact studies. The system allows a deeper insight into motion artifacts and the interplay of the various factors that affect them.

Mesh:

Year:  2014        PMID: 25500614     DOI: 10.1088/0967-3334/36/1/1

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Pareto optimization for electrodes placement: compromises between electrophysiological and practical aspects.

Authors:  Indra Hardian Mulyadi; Patrique Fiedler; Roland Eichardt; Jens Haueisen; Eko Supriyanto
Journal:  Med Biol Eng Comput       Date:  2021-01-26       Impact factor: 2.602

2.  Investigating the possible effect of electrode support structure on motion artifact in wearable bioelectric signal monitoring.

Authors:  Alper Cömert; Jari Hyttinen
Journal:  Biomed Eng Online       Date:  2015-05-15       Impact factor: 2.819

3.  Ultra-conformal drawn-on-skin electronics for multifunctional motion artifact-free sensing and point-of-care treatment.

Authors:  Faheem Ershad; Anish Thukral; Jiping Yue; Phillip Comeaux; Yuntao Lu; Hyunseok Shim; Kyoseung Sim; Nam-In Kim; Zhoulyu Rao; Ross Guevara; Luis Contreras; Fengjiao Pan; Yongcao Zhang; Ying-Shi Guan; Pinyi Yang; Xu Wang; Peng Wang; Xiaoyang Wu; Cunjiang Yu
Journal:  Nat Commun       Date:  2020-07-30       Impact factor: 14.919

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.