Literature DB >> 25498828

Preliminary results using a newly developed projection method to visualize vascular anatomy prior to DIEP flap breast reconstruction.

S Hummelink1, M Hameeteman2, Y Hoogeveen3, C H Slump4, D J O Ulrich2, L J Schultze Kool3.   

Abstract

INTRODUCTION: In a deep inferior epigastric perforator (DIEP) flap breast reconstruction, computed tomography angiography (CTA) is currently considered as the gold standard in preoperative imaging for this procedure. Unidirectional Doppler ultrasound (US) is frequently used; however, this method does not distinguish the main axial vessels from perforator arteries at the height of the fascia, it has a limited penetration depth, and it cannot assess the branching patterns of the deep inferior arteries. A new method and system were developed, which consisted of a video projector preoperatively displaying the location and intramuscular course of the artery perforators and subcutaneous branching on the patient's abdomen.
METHOD: All patients (n=9) underwent a standard protocol: a preoperative CTA was performed and the DIEPs were localized using a unidirectional Doppler probe. In addition, a three-dimensional (3D) reconstruction of the perforator locations based on CTA was projected on the abdomen of the patients. All projected perforator locations were assessed using a unidirectional Doppler probe. The intraoperative results were collected for comparison.
RESULTS: A total of 88 locations were marked with the use of unidirectional Doppler and a total of 100 perforators were projected (p=0.38). In 98 out of 100 projected perforator locations, a Doppler signal was audible. The intraoperative results demonstrate that 19 out of 34 transplanted perforators were correctly identified with unidirectional Doppler (56.9%±31.4%), where the projection method properly revealed 29 locations (84.3%±25.8%) (p=0.030).
CONCLUSION: The projection method is not only capable of providing more information and identifying more perforators used for transplantation than unidirectional Doppler probing but also more accurate in pointing out the corresponding perforator found intraoperatively.
Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computer tomography angiography; DIEP flap breast reconstruction; Perforator mapping; Pico video projector; Virtual planning

Mesh:

Year:  2014        PMID: 25498828     DOI: 10.1016/j.bjps.2014.11.006

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  6 in total

1.  Automating Perforator Flap MRA and CTA Reporting.

Authors:  Christopher J Lange; Nanda Deepa Thimmappa; Srikanth R Boddu; Silvina P Dutruel; Mengchao Pei; Zerwa Farooq; Ashkan Heshmatzadeh Behzadi; Yi Wang; Ramin Zabih; Martin R Prince
Journal:  J Digit Imaging       Date:  2017-06       Impact factor: 4.056

2.  Image Overlay Surgery Based on Augmented Reality: A Systematic Review.

Authors:  Laura Pérez-Pachón; Matthieu Poyade; Terry Lowe; Flora Gröning
Journal:  Adv Exp Med Biol       Date:  2020       Impact factor: 2.622

3.  Stacked and bipedicled abdominal free flaps for breast reconstruction: considerations for shaping.

Authors:  Nakul Gamanlal Patel; Warren Matthew Rozen; Whitney T H Chow; Muhammad Chowdhry; Edmund Fitzgerald O'Connor; Hrsikesa Sharma; Matthew Griffiths; Venkat V Ramakrishnan
Journal:  Gland Surg       Date:  2016-04

Review 4.  Advances in imaging technologies for planning breast reconstruction.

Authors:  Anita T Mohan; Michel Saint-Cyr
Journal:  Gland Surg       Date:  2016-04

5.  Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh.

Authors:  Ignacio Javier Cifuentes; Bruno Leonardo Dagnino; María Carolina Salisbury; María Eliana Perez; Claudia Ortega; Daniela Maldonado
Journal:  Arch Plast Surg       Date:  2018-05-15

6.  Applications and limitations of using patient-specific 3D printed molds in autologous breast reconstruction.

Authors:  Stefan Hummelink; Arico C Verhulst; Thomas J J Maal; Dietmar J O Ulrich
Journal:  Eur J Plast Surg       Date:  2018-06-16