I Craven1, M J Bradburn2, P D Griffiths3. 1. Department of Neuroradiology, Leeds General Infirmary, Leeds, UK. 2. Clinical Trials Research Unit, ScHARR, Sheffield, UK. 3. Academic Unit of Radiology, University of Sheffield, Sheffield, UK. Electronic address: p.griffiths@sheffield.ac.uk.
Abstract
AIM: To estimate the diagnostic performance of ultrasound in detecting agenesis of the corpus callosum (ACC). MATERIALS AND METHODS: A retrospective review was performed of 1722 in utero MRI examinations. All cases were identified in which the fetus had been referred from ultrasonography with a diagnosis of ACC and those in which ACC was given as a diagnosis on the in utero MRI study. The MRI was assumed to provide the correct diagnosis of ACC and descriptive statistics of diagnostic accuracy for ultrasound were calculated. RESULTS: Of the 1722 ultrasound examinations performed, 121 had a diagnosis of ACC and approximately 50% were confirmed at MRI. Forty-two fetuses with ACC not suspected at ultrasonography were also identified at MRI. Ultrasonography had a positive predictive value of 47% (95% CI: 38-56%) and a negative predictive value of 97% (95% CI: 96-98%) for detecting ACC. CONCLUSION: Ultrasound is poor in diagnosing ACC and in utero MRI should be performed if there is any suspicion on antenatal ultrasonography.
AIM: To estimate the diagnostic performance of ultrasound in detecting agenesis of the corpus callosum (ACC). MATERIALS AND METHODS: A retrospective review was performed of 1722 in utero MRI examinations. All cases were identified in which the fetus had been referred from ultrasonography with a diagnosis of ACC and those in which ACC was given as a diagnosis on the in utero MRI study. The MRI was assumed to provide the correct diagnosis of ACC and descriptive statistics of diagnostic accuracy for ultrasound were calculated. RESULTS: Of the 1722 ultrasound examinations performed, 121 had a diagnosis of ACC and approximately 50% were confirmed at MRI. Forty-two fetuses with ACC not suspected at ultrasonography were also identified at MRI. Ultrasonography had a positive predictive value of 47% (95% CI: 38-56%) and a negative predictive value of 97% (95% CI: 96-98%) for detecting ACC. CONCLUSION: Ultrasound is poor in diagnosing ACC and in utero MRI should be performed if there is any suspicion on antenatal ultrasonography.
Authors: M C Diogo; S Glatter; D Prayer; G M Gruber; D Bettelheim; M Weber; G Dovjak; R Seidl; G Kasprian Journal: Ultrasound Obstet Gynecol Date: 2021-07 Impact factor: 8.678