Literature DB >> 25497798

Microfiltration of skim milk and modified skim milk using a 0.1-µm ceramic uniform transmembrane pressure system at temperatures of 50, 55, 60, and 65°C.

E E Hurt1, M C Adams1, D M Barbano2.   

Abstract

Increasing the temperature of microfiltration (MF) to >50°C may allow for operation at higher fluxes and reduce the bacterial growth during MF. However, there is a concern that operating at higher temperatures could cause calcium phosphate precipitation that would lead to membrane fouling. Our objective was to determine the effect of operating a 0.1-µm ceramic uniform transmembrane pressure MF unit at temperatures of 50, 55, 60, and 65°C on membrane fouling and serum protein (SP) removal from skim milk with and without removal of low-molecular-weight soluble milk components by ultrafiltration (UF) before MF at a flux of 54kg/m(2) per hour. For each replicate, 1,000kg of pasteurized skim milk was split into 2 batches. One batch was ultrafiltered (with diafiltration) to remove an average of 89±2% of the lactose and a percentage of the soluble calcium and phosphorus. The retentate from UF was diluted back to the protein concentration of skim milk, creating the diluted UF retentate (DUR). On subsequent days, both the DUR and skim milk were run on the MF unit with the flux maintained at 54kg/m(2) per hour and a concentration factor of 3× and the system run in recycle mode. The temperature of MF was increased in 5°C steps from 50 to 65°C, with a 1-h stabilization period after each increase. During the run, transmembrane pressure was monitored and permeate and retentate samples were taken and analyzed to determine if any changes in SP, calcium, or phosphorus passage through the membrane occurred. Increasing temperature of MF from 50 to 65°C at a flux of 54kg/m(2) per hour did not produce a large increase in membrane fouling when using either skim milk or a DUR as the MF feed type as measured by changes in transmembrane pressure. Increasing the temperature to 65°C only caused a slight reduction in calcium concentration in the permeate (11±3%) that was similar between the 2MF feed types. Increasing processing temperature reduced the percentage of SP removal by the process, but the increased temperature also caused a decrease in casein contamination in the permeate with no evidence of membrane fouling.
Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ceramic microfiltration; processing temperature; serum protein removal

Mesh:

Substances:

Year:  2014        PMID: 25497798     DOI: 10.3168/jds.2014-8775

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  2 in total

1.  Concentration of Immunoglobulins in Microfiltration Permeates of Skim Milk: Impact of Transmembrane Pressure and Temperature on the IgG Transmission Using Different Ceramic Membrane Types and Pore Sizes.

Authors:  Hans-Jürgen Heidebrecht; José Toro-Sierra; Ulrich Kulozik
Journal:  Foods       Date:  2018-06-28

2.  Comparative Assessment of Tubular Ceramic, Spiral Wound, and Hollow Fiber Membrane Microfiltration Module Systems for Milk Protein Fractionation.

Authors:  Roland Schopf; Florian Schmidt; Johanna Linner; Ulrich Kulozik
Journal:  Foods       Date:  2021-03-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.