BACKGROUND: We developed an HPLC-MS/MS method to quantify tamoxifen (2.5-250 ng/ml) and its metabolite (Z)-endoxifen (0.5-50 ng/ml) in dried blood spots.
RESULTS: Extraction recovery of both analytes from Whatman DMPK-A cards was 100% and consistent over time, however, recovery of (Z)-endoxifen from Whatman 903 cards was incomplete and increased upon storage. When SDS, a constituent of the DMPK-A coating, was present during the extraction, recovery improved. The method using DMPK-A cards was validated using bioanalytical guidelines. Additionally, influence of haematocrit (0.29-0.48 L/L), spot volume (20-50 µl) and homogeneity was within limits and both analytes were stable in DBS for at least 4 months.
CONCLUSIONS: The method for the quantification of tamoxifen and (Z)-endoxifen in DBS collected on DMPK-A cards was successfully validated.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25496254     DOI: 10.4155/bio.14.157

Source DB:  PubMed          Journal:  Bioanalysis        ISSN: 1757-6180            Impact factor:   2.681


  4 in total

Review 1.  Dried Blood Spot Technique Applied in Therapeutic Drug Monitoring of Anticancer Drugs: a Review on Conversion Methods to Correlate Plasma and Dried Blood Spot Concentrations.

Authors:  Valentina Iacuzzi; Bianca Posocco; Martina Zanchetta; Sara Gagno; Ariana Soledad Poetto; Michela Guardascione; Giuseppe Toffoli
Journal:  Pharm Res       Date:  2021-04-12       Impact factor: 4.200

2.  New UPLC-MS/MS assay for the determination of tamoxifen and its metabolites in human plasma, application to patients.

Authors:  Christine Bobin-Dubigeon; Mario Campone; Elsa Rossignol; Estelle Salaun; Marie-Bernadette Amiand; Jean-Marie Bard
Journal:  Future Sci OA       Date:  2019-03-22

3.  Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients.

Authors:  Baitha Palanggatan Maggadani; Samuel J Haryono; Marcellino Ryan Rinaldi; Yahdiana Harahap
Journal:  Drug Des Devel Ther       Date:  2021-06-04       Impact factor: 4.162

4.  Analysis of tamoxifen and its metabolites in dried blood spot and volumetric absorptive microsampling: comparison and clinical application.

Authors:  Baitha Palanggatan Maggadani; Yahdiana Harahap; Samuel J Haryono; Christoffel William Putra Untu
Journal:  Heliyon       Date:  2021-06-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.