Literature DB >> 25493415

Time-resolved perfusion imaging at the angiography suite: preclinical comparison of a new flat-detector application to computed tomography perfusion.

Julian H W Jürgens1, Nadine Schulz, Christian Wybranski, Max Seidensticker, Sebastian Streit, Jan Brauner, Walter A Wohlgemuth, Yu Deuerling-Zheng, Jens Ricke, Oliver Dudeck.   

Abstract

OBJECTIVES: The objective of this study was to compare the parameter maps of a new flat-panel detector application for time-resolved perfusion imaging in the angiography room (FD-CTP) with computed tomography perfusion (CTP) in an experimental tumor model.
MATERIALS AND METHODS: Twenty-four VX2 tumors were implanted into the hind legs of 12 rabbits. Three weeks later, FD-CTP (Artis zeego; Siemens) and CTP (SOMATOM Definition AS +; Siemens) were performed. The parameter maps for the FD-CTP were calculated using a prototype software, and those for the CTP were calculated with VPCT-body software on a dedicated syngo MultiModality Workplace. The parameters were compared using Pearson product-moment correlation coefficient and linear regression analysis.
RESULTS: The Pearson product-moment correlation coefficient showed good correlation values for both the intratumoral blood volume of 0.848 (P < 0.01) and the blood flow of 0.698 (P < 0.01). The linear regression analysis of the perfusion between FD-CTP and CTP showed for the blood volume a regression equation y = 4.44x + 36.72 (P < 0.01) and for the blood flow y = 0.75x + 14.61 (P < 0.01).
CONCLUSIONS: This preclinical study provides evidence that FD-CTP allows a time-resolved (dynamic) perfusion imaging of tumors similar to CTP, which provides the basis for clinical applications such as the assessment of tumor response to locoregional therapies directly in the angiography suite.

Entities:  

Mesh:

Year:  2015        PMID: 25493415     DOI: 10.1097/RLI.0000000000000107

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

Review 1.  Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

Authors:  A Doerfler; P Gölitz; T Engelhorn; S Kloska; T Struffert
Journal:  Clin Neuroradiol       Date:  2015-06-20       Impact factor: 3.649

2.  Curved periacetabular osteotomy using intraoperative real-time 3-dimensional computed tomography with a robotic C-arm system: A case report.

Authors:  Ariha Goshi; Shigeo Fukunishi; Shohei Okahisa; Taishi Okada; Shinichi Yoshiya
Journal:  Medicine (Baltimore)       Date:  2018-11       Impact factor: 1.817

3.  Use of perfusional CBCT imaging for intraprocedural evaluation of endovascular treatment in patients with diabetic foot: a concept paper.

Authors:  Martina Gurgitano; Giulia Signorelli; Giovanni Maria Rodà; Alessandro Liguori; Marco Pandolfi; Giuseppe Granata; Antonio Arrichiello; Anna Maria Ierardi; Aldo Paolucci; Gianpaolo Carrafiello
Journal:  Acta Biomed       Date:  2020-09-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.