Literature DB >> 25491981

Low elastic modulus Ti-Ta alloys for load-bearing permanent implants: enhancing the biodegradation resistance by electrochemical surface engineering.

Jazmin Kesteven1, M Bobby Kannan2, Rhys Walter1, Hadis Khakbaz1, Han-Choel Choe3.   

Abstract

In this study, the in vitro degradation behaviour of titanium-tantalum (Ti-Ta) alloys (10-30 wt.% Ta) was investigated and compared with conventional implant materials, i.e., commercially pure titanium (Cp-Ti) and titanium-aluminium-vanadium (Ti6Al4V) alloy. Among the three Ti-Ta alloys studied, the Ti20Ta (6.3×10(-4) mm/y) exhibited the lowest degradation rate, followed by Ti30Ta (1.2×10(-3) mm/y) and Ti10Ta (1.4×10(-3) mm/y). All the Ti-Ta alloys exhibited lower degradation rate than that of Cp-Ti (1.8×10(-3) mm/y), which suggests that Ta addition to Ti is beneficial. As compared to Ti6Al4V alloy (8.1×10(-4) mm/y), the degradation rate of Ti20Ta alloy was lower by ~22%. However, the Ti30Ta alloy, which has closer elastic modulus to that of natural bone, showed ~48% higher degradation rate than that of Ti6Al4V alloy. Hence, to improve the degradation performance of Ti30Ta alloy, an intermediate thin porous layer was formed electrochemically on the alloy followed by calcium phosphate (CaP) electrodeposition. The coated Ti30Ta alloy (3.8×10(-3) mm/y) showed ~53% lower degradation rate than that of Ti6Al4V alloy. Thus, the study suggests that CaP coated Ti30Ta alloy can be a viable material for load-bearing permanent implants.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anodization; Biomaterials; Calcium phosphate; Degradation; Tantalum; Titanium

Mesh:

Substances:

Year:  2014        PMID: 25491981     DOI: 10.1016/j.msec.2014.10.038

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  2 in total

1.  Preparation and Properties of Bulk and Porous Ti-Ta-Ag Biomedical Alloys.

Authors:  Grzegorz Adamek; Mikolaj Kozlowski; Adam Junka; Piotr Siwak; Jaroslaw Jakubowicz
Journal:  Materials (Basel)       Date:  2022-06-18       Impact factor: 3.748

2.  Sintering Analysis of Porous Ti/xTa Alloys Fabricated from Elemental Powders.

Authors:  Rogelio Macias; Pedro Garnica-Gonzalez; Luis Olmos; Omar Jimenez; Jorge Chavez; Octavio Vazquez; Francisco Alvarado-Hernandez; Dante Arteaga
Journal:  Materials (Basel)       Date:  2022-09-21       Impact factor: 3.748

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.