Jiubin Tan, Chao Wang, Yuan Wang, Weibo Wang, Jian Liu, Richard Leach, Ling Hao.
Abstract
For fine stitching of multiwindow wide-spectrum detectors, an aspherical Schwarzschild objective with an effective working distance of 525 mm has been realized for chromatic aberration-free imaging in 400-900 nm wavelength range and with a numerical aperture of 0.13. A theoretical approach for analytical design of an initial configuration has been modeled using an on-axis Taylor series expansion, and the beam obscuration ratio (OR) has been controlled down to 4%. In comparison against the theoretical spherical-based Schwarzschild objective, 77.5% of the OR has been reduced for improved contrast.Year: 2014 PMID: 25490656 DOI: 10.1364/OL.39.006699
Source DB: PubMed Journal: Opt Lett ISSN: 0146-9592 Impact factor: 3.776