Literature DB >> 25490495

Single-shot phase imaging with a coded aperture.

Ryoichi Horisaki, Yusuke Ogura, Masahiko Aino, Jun Tanida.   

Abstract

We present a method of quantitatively acquiring a large complex field, containing not only amplitude information but also phase information, based on single-shot phase imaging with a coded aperture (SPICA). In SPICA, the propagating field from an object illuminated by partially coherent visible light is sieved by a coded mask, and the sieved field propagates to an image sensor, where it is captured. The sieved field is recovered from the single captured intensity image via a phase retrieval algorithm with an amplitude support constraint using the mask pattern, and then the object's complex field is reconstructed from the recovered sieved field by an algorithm employing a sparsity constraint based on compressive sensing. The system model and the theoretical bounds of SPICA are derived. We also verified the concept with numerical demonstrations.

Year:  2014        PMID: 25490495     DOI: 10.1364/OL.39.006466

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  6 in total

1.  Single-frame 3D fluorescence microscopy with ultraminiature lensless FlatScope.

Authors:  Jesse K Adams; Vivek Boominathan; Benjamin W Avants; Daniel G Vercosa; Fan Ye; Richard G Baraniuk; Jacob T Robinson; Ashok Veeraraghavan
Journal:  Sci Adv       Date:  2017-12-08       Impact factor: 14.136

2.  WISH: wavefront imaging sensor with high resolution.

Authors:  Yicheng Wu; Manoj Kumar Sharma; Ashok Veeraraghavan
Journal:  Light Sci Appl       Date:  2019-05-01       Impact factor: 17.782

3.  Quantitative phase and polarization imaging through an optical fiber applied to detection of early esophageal tumorigenesis.

Authors:  George S D Gordon; James Joseph; Maria P Alcolea; Travis Sawyer; Calum Williams; Catherine R M Fitzpatrick; Philip H Jones; Massimiliano di Pietro; Rebecca C Fitzgerald; Timothy D Wilkinson; Sarah E Bohndiek
Journal:  J Biomed Opt       Date:  2019-12       Impact factor: 3.170

4.  In vivo lensless microscopy via a phase mask generating diffraction patterns with high-contrast contours.

Authors:  Jesse K Adams; Dong Yan; Jimin Wu; Vivek Boominathan; Sibo Gao; Alex V Rodriguez; Soonyoung Kim; Jennifer Carns; Rebecca Richards-Kortum; Caleb Kemere; Ashok Veeraraghavan; Jacob T Robinson
Journal:  Nat Biomed Eng       Date:  2022-03-07       Impact factor: 29.234

5.  Robustness to misalignment of low-cost, compact quantitative phase imaging architectures.

Authors:  Catherine R M Fitzpatrick; Abby Wilson; Travis W Sawyer; Peter J Christopher; Timothy D Wilkinson; Sarah E Bohndiek; George S D Gordon
Journal:  OSA Contin       Date:  2020-09-17

Review 6.  3D Imaging Based on Depth Measurement Technologies.

Authors:  Ni Chen; Chao Zuo; Edmund Y Lam; Byoungho Lee
Journal:  Sensors (Basel)       Date:  2018-10-31       Impact factor: 3.576