Literature DB >> 25490249

P-wave indices as predictors of atrial fibrillation recurrence after pulmonary vein isolation in normal left atrial size.

Giacomo Mugnai1, Gian-Battista Chierchia, Carlo de Asmundis, Justo Juliá, Giulio Conte, Juan Sieira-Moret, Lucio Capulzini, Kristel Wauters, Moises Rodriguez-Mañero, Giuseppe Ciconte, Giannis Baltogiannis, Giacomo Di Giovanni, Yukio Saitoh, Pedro Brugada.   

Abstract

AIMS: Prolonged P-wave duration and dispersion are universally accepted noninvasive markers for atrial electrical remodeling. Our aim was to analyze P-wave indices as predictors of atrial fibrillation recurrence after pulmonary vein isolation in patients with normal left atrial size.
METHODS: From January 2008 to December 2011, 426 patients with drug-resistant symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation as an index procedure by conventional radiofrequency or cryoballoon ablation in our center. Patients with left atrial dilatation, poor-quality electrocardiograms, atrial pacemaker stimulation, and those undergoing repeat procedures were excluded. A total of 201 patients were analyzed during a mean follow-up of 22 ± 16 months.
RESULTS: Patients with prolonged P-wave duration had higher rates of atrial fibrillation recurrences compared with those without prolonged P-wave duration (49 vs. 14%; P < 0.001). Atrial fibrillation recurrence was significantly associated with prolonged P-wave duration (129 ± 13 vs. 119 ± 11 ms; P < 0.001) and P-wave dispersion (54 ± 12 vs. 42 ± 10 ms; P < 0.001) compared with those who remained in sinus rhythm. P-wave duration and dispersion were independently associated with atrial fibrillation recurrence (hazard ratio 1.045, 95% confidence interval 1.027-1.063, P < 0.001; and hazard ratio 1.049, 95% confidence interval 1.022-1.078, P < 0.001, respectively), after adjusting for left atrial size and age.
CONCLUSION: Prolonged P-wave duration and dispersion were found to be independently associated with higher recurrence rates of atrial fibrillation after pulmonary vein isolation in patients with normal left atrial dimension. Therefore, a prolongation of P-wave indices may help to identify those patients in whom electrical remodeling has already occurred and a more extensive ablation may be indicated.

Entities:  

Mesh:

Year:  2016        PMID: 25490249     DOI: 10.2459/JCM.0000000000000220

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  7 in total

1.  Prolonged P-wave duration in sinus rhythm pre-ablation is associated with atrial fibrillation recurrence after pulmonary vein isolation-A systematic review and meta-analysis.

Authors:  Raymond Pranata; Emir Yonas; Rachel Vania
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-04-14       Impact factor: 1.468

2.  Electrocardiographic P-Wave Duration, QT Interval, T Peak to End Interval and Tp-e/QT Ratio in Pregnancy with Respect to Trimesters.

Authors:  Asli Tanindi; Nilufer Akgun; Emre Goksan Pabuccu; Aslı Yarci Gursoy; Ebru Yüce; Hasan Fehmi Tore; Candan Iltemir Duvan
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-06-18       Impact factor: 1.468

3.  Impact of a prolonged interatrial conduction time for predicting the recurrence of atrial fibrillation after circumferential pulmonary vein isolation of persistent atrial fibrillation.

Authors:  Satoshi Higuchi; Koichiro Ejima; Morio Shoda; Eri Yamamoto; Yuji Iwanami; Daigo Yagishita; Nobuhisa Hagiwara
Journal:  Heart Vessels       Date:  2018-10-05       Impact factor: 2.037

4.  Atrial electrocardiography in obesity and hypertension: Clinical insights from the Polish-Norwegian Study (PONS).

Authors:  Georgeta D Vaidean; Marta Manczuk; Jared W Magnani
Journal:  Obesity (Silver Spring)       Date:  2016-10-18       Impact factor: 5.002

Review 5.  P-wave dispersion: an update.

Authors:  Andrés Ricardo Pérez-Riera; Luiz Carlos de Abreu; Raimundo Barbosa-Barros; José Grindler; Acácio Fernandes-Cardoso; Adrian Baranchuk
Journal:  Indian Pacing Electrophysiol J       Date:  2016-10-20

6.  The assessment of P-wave dispersion and myocardial repolarization parameters in patients with chronic kidney disease.

Authors:  Korhan Kollu; Lutfullah Altintepe; Cevdet Duran; Mustafa Topal; Samil Ecirli
Journal:  Ren Fail       Date:  2018-11       Impact factor: 2.606

7.  Usefulness of Morphology-Voltage-P-wave duration (MVP) score as a predictor of atrial fibrillation recurrence after pulmonary vein isolation.

Authors:  Na Yang; Ning Yan; Guangzhi Cong; Zhen Yang; Mohan Wang; Shaobin Jia
Journal:  Ann Noninvasive Electrocardiol       Date:  2020-06-21       Impact factor: 1.468

  7 in total