Literature DB >> 25489499

Flap donor site size reduction with substratum horizontal mattress suture.

Mohammad Jalilimanesh1.   

Abstract

BACKGROUND: Closure of donor site of the flap has special problems. Reduction of this site will decrease the morbidity of operation. In this study, we present our experience in donor site size reduction.
METHODS: Between 2006 and 2008, 15 patients with skin and soft tissue defects underwent operation. In all patients, coverage of defect was performed with various flaps. Substratum horizontal mattress suture was used to reduce donor site dimensions. In all 15 patients, size of the flaps, the defect after the flap elevation and the scar size were measured.
RESULTS: The mean size of the flap, the defect after flap elevation, and the scar after 3 months were 43.9 cm(2), 69.4 cm(2), and 32.2 cm(2), respectively. There was 46.5% reduction in the donor site after using this suture.
CONCLUSION: The substratum horizontal mattress suture was shown to de- crease the donor site dimensions and also its scar size in flap surgery. This suture is highly recommend in order to reduce donor site dimensions.

Entities:  

Keywords:  Donor site; Flap surgery; Skin graft

Year:  2013        PMID: 25489499      PMCID: PMC4238329     

Source DB:  PubMed          Journal:  World J Plast Surg        ISSN: 2228-7914


  5 in total

1.  Incidence of donor site skin graft loss requiring surgical intervention with the radial forearm free flap.

Authors:  Kevin S Emerick; Daniel G Deschler
Journal:  Head Neck       Date:  2007-06       Impact factor: 3.147

2.  Evaluation of the donor site in patients who underwent reconstruction with a free radial forearm flap.

Authors:  Osamu Ito; Hiroharu H Igawa; Shigehiko Suzuki; Gan Muneuchi; Takeshi Kawazoe; Yasumi Saso; Masayuki Onodera; Susam Park; Yuiro Hata
Journal:  J Reconstr Microsurg       Date:  2005-02       Impact factor: 2.873

3.  Dermis graft for wound coverage.

Authors:  Seung-Kyu Han; Tae-Hwan Yoon; Jung-Bae Kim; Woo-Kyung Kim
Journal:  Plast Reconstr Surg       Date:  2007-07       Impact factor: 4.730

4.  Closure of radial forearm free flap donor site defect with a local meshed full-thickness skin graft: a retrospective study of an original technique.

Authors:  Abbas Karimi; Pierre Mahy; Hervé Reychler
Journal:  J Craniomaxillofac Surg       Date:  2007-11-26       Impact factor: 2.078

5.  An alternative method to minimize pain in the split-thickness skin graft donor site.

Authors:  Mithat Akan; Serkan Yildirim; Aykut Misirlioğlu; Gürhan Ulusoy; Tayfun Aköz; Gülden Avci
Journal:  Plast Reconstr Surg       Date:  2003-06       Impact factor: 4.730

  5 in total