Literature DB >> 25486630

An experimental study to investigate biomechanical aspects of the initial stability of press-fit implants.

Sanaz Berahmani1, Dennis Janssen2, Sal van Kessel2, David Wolfson3, Maarten de Waal Malefijt4, Pieter Buma2, Nico Verdonschot5.   

Abstract

Initial fixation of press-fit implants depends on interference fit, surface morphology, and bone material properties. To understand the biomechanical effect of each factor and their interactions, the pull-out strength of seven types of CoCrMo tapered implants, with four different interference fits, three different surface morphologies (low, medium and high roughness), and at two time points (0 and 30 min) were tested in trabecular bone with varying density. The effect of interference fit on pull-out strength depended on the surface morphology and time. In contrast with our expectations, samples with a higher roughness had a lower pull-out strength. We found a similar magnitude of bone damage for the different surface morphologies, but the type of damage was different, with bone compaction versus bone abrasion for low and high frictional surfaces, respectively. This explains a reduced sensitivity of fixation strength to bone mineral density in the latter group. In addition, a reduction in fixation strength after a waiting period only occurred for the low frictional specimens. Our study demonstrates that it is essential to evaluate the interplay between different factors and emphasizes the importance of testing in natural bone in order to optimize the initial stability of press-fit implants.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25486630     DOI: 10.1016/j.jmbbm.2014.11.014

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  Optimal interference of the tibial component of the cementless Oxford Unicompartmental Knee Replacement.

Authors:  S Campi; S J Mellon; D Ridley; B Foulke; C A F Dodd; H G Pandit; D W Murray
Journal:  Bone Joint Res       Date:  2018-05-05       Impact factor: 5.853

3.  Mathematical Modelling of Destabilization Stress Factors of Stable-Elastic Fixation of Distal Trans- and Suprasyndesmotic Fibular Fractures.

Authors:  Andriy Chuzhak; Vadym Sulyma; Lіubomyr Ropyak; Andrii Velychkovych; Vasyl Vytvytskyi
Journal:  J Healthc Eng       Date:  2021-11-09       Impact factor: 2.682

4.  Additive manufactured push-fit implant fixation with screw-strength pull out.

Authors:  Richard J van Arkel; Shaaz Ghouse; Piers E Milner; Jonathan R T Jeffers
Journal:  J Orthop Res       Date:  2017-11-22       Impact factor: 3.494

5.  Measurement of Internal Implantation Strains in Analogue Bone Using DVC.

Authors:  Alexander Marter; Charles Burson-Thomas; Alexander Dickinson; Kathryn Rankin; Mark Mavrogordato; Fabrice Pierron; Martin Browne
Journal:  Materials (Basel)       Date:  2020-09-12       Impact factor: 3.623