This work presents the implementation and testing of several radon mitigation techniques in a pilot house in the radon prone area of Băiţa-Ştei in NW part of Romania. Radon diagnostic investigations in the pilot house showed that the main source of radon was the building sub-soil and the soil near the house. The applied techniques were based on the depressurization and pressurization of the building sub-soil, on the combination of the soil depressurization system by an electric and an eolian fans. Also, there was made an application of a radon barrier membrane and a testing by the combination of the radon membrane by the soil depressurization system. Finally, the better obtained remedial efficiency was about 85%.Keywords: Indoor radon; Radon barrier membrane; Radon mitigation techniques; Radon-prone area; Soil depressurization
Mesh:
Substances:
Year: 2014 PMID: 25483354 DOI: 10.1016/j.jenvrad.2014.11.007