Literature DB >> 25483314

Fast generation of T2* maps in the entire range of clinical interest: application to thalassemia major patients.

Vincenzo Positano1, Antonella Meloni2, Maria Filomena Santarelli3, Calogera Gerardi4, Pier Paolo Bitti5, Carla Cirotto6, Daniele De Marchi2, Cristina Salvatori2, Luigi Landini7, Alessia Pepe2.   

Abstract

T2* maps obtained by the processing of multiecho MR sequences can be useful in several clinical applications. T2* map generation procedures should join a processing time compatible with on-line image analysis with a good precision in the entire T2* range of clinical interest. Fast generation of T2* maps can be achieved by the estimation of the T2* values by the weighted linear fitting of the logarithm of the signal (WLSL) method. This approach fails if the signal decay diverges from a pure exponential decay, as happens at low T2* values where the rapid decay in the signal intensity leads to a plateau in the later echo times (TE). The proposed method implements the automatic truncation of the signal decay curves to be fitted in order to compensate for the signal collapse at low T2* values, allowing the extension of the WLSL method through the entire clinical range of T2* values. Validation was performed on synthetic images and on 60 thalassemia major patients with different levels of myocardial iron overload. Phantom experiments showed that a 5% fitting error threshold represented the best compromise between T2* value measurement precision and processing time. A good agreement was found between T2* map pixel-wise measurements and ROI-based measurements performed by expert readers (CoV=1.84% in global heart T2*, CoV=5.8% in segmental analysis). In conclusion, the developed procedure was effective in generating correct T2* maps for the entire T2* clinical range.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Iron overload; Magnetic resonance imaging; Relaxometry; T2(⁎) mapping; Thalassemia

Mesh:

Year:  2014        PMID: 25483314     DOI: 10.1016/j.compbiomed.2014.10.020

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  8 in total

Review 1.  Clinical application of CMR in cardiomyopathies: evolving concepts and techniques : A position paper of myocardial and pericardial diseases and cardiac magnetic resonance working groups of Italian society of cardiology.

Authors:  Marco Merlo; Giulia Gagno; Anna Baritussio; Barbara Bauce; Elena Biagini; Marco Canepa; Alberto Cipriani; Silvia Castelletti; Santo Dellegrottaglie; Andrea Igoren Guaricci; Massimo Imazio; Giuseppe Limongelli; Maria Beatrice Musumeci; Vanda Parisi; Silvia Pica; Gianluca Pontone; Giancarlo Todiere; Camilla Torlasco; Cristina Basso; Gianfranco Sinagra; Pasquale Perrone Filardi; Ciro Indolfi; Camillo Autore; Andrea Barison
Journal:  Heart Fail Rev       Date:  2022-05-10       Impact factor: 4.654

Review 2.  Cardiovascular magnetic resonance for the diagnosis and management of heart failure with preserved ejection fraction.

Authors:  Andrea Barison; Alberto Aimo; Giancarlo Todiere; Chrysanthos Grigoratos; Giovanni Donato Aquaro; Michele Emdin
Journal:  Heart Fail Rev       Date:  2022-01       Impact factor: 4.214

3.  Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2* determination.

Authors:  Pandji Triadyaksa; Niek H J Prakken; Jelle Overbosch; Robin B Peters; J Martijn van Swieten; Matthijs Oudkerk; Paul E Sijens
Journal:  MAGMA       Date:  2016-12-16       Impact factor: 2.310

4.  The Link of Pancreatic Iron with Glucose Metabolism and Cardiac Iron in Thalassemia Intermedia: A Large, Multicenter Observational Study.

Authors:  Antonella Meloni; Laura Pistoia; Maria Rita Gamberini; Paolo Ricchi; Valerio Cecinati; Francesco Sorrentino; Liana Cuccia; Massimo Allò; Riccardo Righi; Priscilla Fina; Ada Riva; Stefania Renne; Giuseppe Peritore; Stefano Dalmiani; Vincenzo Positano; Emilio Quaia; Filippo Cademartiri; Alessia Pepe
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

5.  T2* assessment of the three coronary artery territories of the left ventricular wall by different monoexponential truncation methods.

Authors:  Pandji Triadyaksa; Jelle Overbosch; Matthijs Oudkerk; Paul Eduard Sijens
Journal:  MAGMA       Date:  2022-04-18       Impact factor: 2.533

6.  Cardiovascular magnetic resonance native T2 and T2* quantitative values for cardiomyopathies and heart transplantations: a systematic review and meta-analysis.

Authors:  G J H Snel; M van den Boomen; L M Hernandez; C T Nguyen; D E Sosnovik; B K Velthuis; R H J A Slart; R J H Borra; N H J Prakken
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-11       Impact factor: 5.364

Review 7.  Cardiac T2 * mapping: Techniques and clinical applications.

Authors:  Pandji Triadyaksa; Matthijs Oudkerk; Paul E Sijens
Journal:  J Magn Reson Imaging       Date:  2019-12-14       Impact factor: 4.813

8.  Setting for "Normal" Serum Ferritin Levels in Patients with Transfusion-Dependent Thalassemia: Our Current Strategy.

Authors:  Anna Spasiano; Antonella Meloni; Silvia Costantini; Emilio Quaia; Filippo Cademartiri; Patrizia Cinque; Alessia Pepe; Paolo Ricchi
Journal:  J Clin Med       Date:  2021-12-20       Impact factor: 4.241