Literature DB >> 25480764

Pulmonary artery catheter.

Stephanie Whitener1, Ryan Konoske2, Jonathan B Mark3.   

Abstract

Since its inception, the pulmonary artery catheter has enjoyed widespread use in both medical and surgical critically ill patients. It has also endured criticism and skepticism about its benefit in these patient populations. By providing information such as cardiac output, mixed venous oxygen saturation, and intracardiac pressures, the pulmonary artery catheter may improve care of the most complex critically ill patients in the intensive care unit and the operating room. With its ability to transduce pressures through multiple ports, one of the primary clinical uses for pulmonary artery catheters is real-time intracardiac pressure monitoring. Correct interpretation of the waveforms is essential to confirming correct placement of the catheter to ensure accurate data are recorded. Major complications related to catheter placement are infrequent, but misinterpretation of monitored data is not uncommon and has led many to question the utility of the pulmonary artery catheter. The evidence to date suggests that the use of the catheter does not change mortality in many critically ill patients and may expose these patients to a higher rate of complications. However, additional clinical trials are needed, particularly in the most complex critically ill patients, who have generally been excluded from many of the research trials performed to date.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  continuous cardiac output monitoring; intracardiac pressure monitoring; pulmonary artery catheter

Mesh:

Year:  2014        PMID: 25480764     DOI: 10.1016/j.bpa.2014.08.003

Source DB:  PubMed          Journal:  Best Pract Res Clin Anaesthesiol        ISSN: 1521-6896


  7 in total

1.  Hemodynamic Parameters in the Assessment of Fluid Status in a Porcine Hemorrhage and Resuscitation Model.

Authors:  Eric S Wise; Kyle M Hocking; Monica E Polcz; Gregory J Beilman; Colleen M Brophy; Jenna H Sobey; Philip J Leisy; Roy K Kiberenge; Bret D Alvis
Journal:  Anesthesiology       Date:  2021-04-01       Impact factor: 7.892

2.  Bioreactance and fourth-generation pulse contour methods in monitoring cardiac index during off-pump coronary artery bypass surgery.

Authors:  Laura Anneli Ylikauma; Pasi Petteri Ohtonen; Tiina Maria Erkinaro; Merja Annika Vakkala; Janne Henrik Liisanantti; Jari Uolevi Satta; Tatu Sakari Juvonen; Timo Ilari Kaakinen
Journal:  J Clin Monit Comput       Date:  2021-05-26       Impact factor: 1.977

3.  Comparison of in vivo antibacterial and antithrombotic activities of two types of pulmonary artery catheters in pig.

Authors:  Jung Wook Han; Yeon Soo Shin; Jung Ju Kim; Ho Sung Son
Journal:  Biomater Res       Date:  2017-11-15

4.  The role of the maximal first derivative of the radial pulse wave (Rad dP/dtmax) in monitoring cardiac function.

Authors:  Hao Guo; Jing Zhou; Zhi Wang; Li-Kun Liu; Shu-Zhen Yu; Hong-Wei Cai
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 2.895

5.  Autologous red blood cell transfusion does not result in a more profound increase in pulmonary capillary wedge pressure compared to saline in critically ill patients: A randomized crossover trial.

Authors:  Joachim J Bosboom; Robert B Klanderman; Lotte E Terwindt; Esther B Bulle; Marije Wijnberge; Susanne Eberl; Antoine H Driessen; Toon A Winkelman; Bart F Geerts; Denise P Veelo; Markus W Hollmann; Alexander P J Vlaar
Journal:  Vox Sang       Date:  2022-05-13       Impact factor: 2.996

Review 6.  Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials.

Authors:  Rishi P Mathew; Timothy Alexander; Vimal Patel; Gavin Low
Journal:  SA J Radiol       Date:  2019-07-29

7.  Cephalad misplacement of a pulmonary artery catheter in a patient with a preexisting Hickman catheter.

Authors:  Hoon Choi; Joon Pyo Jeon; Jaewon Huh; Youme Kim; Wonjung Hwang
Journal:  BMC Anesthesiol       Date:  2021-06-01       Impact factor: 2.217

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.