Modelling the electrophoretic migration behaviour of peptides and glycopeptides from glycoprotein digests in capillary electrophoresis-mass spectrometry.

Albert Barroso1, Estela Giménez1, Fernando Benavente1, José Barbosa1, Victoria Sanz-Nebot2.   

Abstract

In this study, the classical semiempirical relationships between the electrophoretic mobility and the charge-to-mass ratio (me vs. q/M(α)) were used to model the migration behaviour of peptides and glycopeptides originated from the digestion of recombinant human erythropoietin (rhEPO), a biologically and therapeutically relevant glycoprotein. The Stoke's law (α=1/3), the classical polymer model (α=1/2) and the Offord's surface law (α=2/3) were evaluated to predict migration of peptides and glycopeptides, with and without sialic acids (SiA), in rhEPO digested with trypsin and trypsin-neuraminidase. The Stoke's law resulted in better correlations for the set of peptides used to evaluate the models, while glycopeptides fitted better with the classical polymer model. Once predicted migration times with both models, it was easy to simulate their separation electropherogram. Results were later validated predicting migration and simulating separation of a different set of rhEPO glycopeptides and also human transferrin (Tf) peptides and glycopeptides. The excellent agreement between the experimental and the simulated electropherograms with rhEPO and Tf digests confirmed the potential applicability of this simple strategy to predict, in general, the peptide-glycopeptide electrophoretic map of any digested glycoprotein.
Copyright © 2014. Published by Elsevier B.V.

Entities:  

Keywords:  Capillary electrophoresis; Glycopeptides; Mass spectrometry; Migration prediction; rhEPO

Mesh:

Substances:

Year:  2014        PMID: 25479881     DOI: 10.1016/j.aca.2014.10.038

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Predicting Electrophoretic Mobility of Tryptic Peptides for High-Throughput CZE-MS Analysis.

Authors:  Oleg V Krokhin; Geoffrey Anderson; Vic Spicer; Liangliang Sun; Norman J Dovichi
Journal:  Anal Chem       Date:  2017-01-19       Impact factor: 6.986

2.  High-Sensitivity Glycoproteomic Analysis of Biological Samples by CZE-ESI-MS.

Authors:  W Wang; G S M Lageveen-Kammeijer
Journal:  Methods Mol Biol       Date:  2022

Review 3.  Mass Spectrometry Approaches to Glycomic and Glycoproteomic Analyses.

Authors:  L Renee Ruhaak; Gege Xu; Qiongyu Li; Elisha Goonatilleke; Carlito B Lebrilla
Journal:  Chem Rev       Date:  2018-03-19       Impact factor: 60.622

4.  Site-Specific N-Linked Glycosylation Analysis of Human Carcinoembryonic Antigen by Sheathless Capillary Electrophoresis-Tandem Mass Spectrometry.

Authors:  Laura Pont; Valeriia Kuzyk; Fernando Benavente; Victoria Sanz-Nebot; Oleg A Mayboroda; Manfred Wuhrer; Guinevere S M Lageveen-Kammeijer
Journal:  J Proteome Res       Date:  2021-02-09       Impact factor: 4.466

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.