Literature DB >> 25479863

Fast sequential multi-element determination of major and minor elements in environmental samples and drinking waters by high-resolution continuum source flame atomic absorption spectrometry.

Beatriz Gómez-Nieto1, Ma Jesús Gismera2, Ma Teresa Sevilla1, Jesús R Procopio1.   

Abstract

The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  High-resolution continuum source flame AAS; Low sample consumption; Metal analysis in environmental samples and drinking waters; Multi-element determination; Side pixel registration

Mesh:

Substances:

Year:  2014        PMID: 25479863     DOI: 10.1016/j.aca.2014.10.051

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  The direct and accurate determination of major elements Ca, K, Mg and Na in water by HR-ICPMS.

Authors:  Kenny Nadeau; Zoltán Mester; Lu Yang
Journal:  Sci Rep       Date:  2018-12-10       Impact factor: 4.379