Literature DB >> 25479451

Cirrus HD-OCT short-term repeatability of clinical retinal nerve fiber layer measurements.

Elizabeth Wong1, Nayuta Yoshioka, Michael Kalloniatis, Barbara Zangerl.   

Abstract

PURPOSE: The detection of changes in the retinal nerve fiber layer (RNFL) as measured by optical coherence tomography (OCT) is crucial in glaucoma diagnosis and management. We investigated the short-term repeatability of peripapillary RNFL measurements in a commercially available spectral domain OCT focusing on a broad clinical spectrum of patients.
METHODS: Two consecutive peripapillary RNFL measurements were taken on 227 eyes with Cirrus HD-OCT (Carl Zeiss Meditec, Version 6.5 software) using the optic disc 200 × 200 protocol. Repeatability was assessed as Bland-Altman limits of agreement and intraclass coefficients (ICCs).
RESULTS: Limits of agreement showed the greatest variability in the superior RNFL quadrant at ±7.5 μm and the least variability in the temporal quadrant at ±5.2 μm. The short-term repeatability for the average RNFL thickness resulted in an ICC of 0.98 and variability of 3.81 μm. Individual quadrants were similar, excepting the nasal RNFL quadrant with an ICC of 0.94. Inferior and temporal quadrants were the most repeatable with a variability of 2 to 3% instrument error.
CONCLUSIONS: Cirrus HD-OCT has excellent short-term repeatability for peripapillary RNFL measurements in a mixed patient cohort. Retinal nerve fiber layer measurements are less reliable in the nasal RNFL quadrant. As other quadrants are used in glaucoma diagnosis, the detection of glaucomatous progression would be reliable.

Entities:  

Mesh:

Year:  2015        PMID: 25479451     DOI: 10.1097/OPX.0000000000000452

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  Progressive retinal structure abnormalities in multiple system atrophy.

Authors:  Carlos E Mendoza-Santiesteban; Jose-Alberto Palma; Jose Martinez; Lucy Norcliffe-Kaufmann; Thomas R Hedges; Horacio Kaufmann
Journal:  Mov Disord       Date:  2015-09-11       Impact factor: 10.338

2.  Repeatability Using Automatic Tracing with Canon OCT- HS100 and Zeiss Cirrus HD-OCT 5000.

Authors:  Rune Brautaset; Ulrika Birkeldh; Petra Frehr Alstig; Petra Wikén; Maria Nilsson
Journal:  PLoS One       Date:  2016-02-11       Impact factor: 3.240

3.  Reconciling visual field defects and retinal nerve fibre layer asymmetric patterns in retrograde degeneration: an extended case series.

Authors:  Barbara Zangerl; Andrew Whatham; Juno Kim; Agnes Choi; Nagi N Assaad; Michael P Hennessy; Michael Kalloniatis
Journal:  Clin Exp Optom       Date:  2016-10-11       Impact factor: 2.742

4.  Prediction of visual field defects from macular optical coherence tomography in glaucoma using cluster analysis.

Authors:  Janelle Tong; David Alonso-Caneiro; Michael Kalloniatis; Barbara Zangerl
Journal:  Ophthalmic Physiol Opt       Date:  2022-05-22       Impact factor: 3.992

5.  Progression of optic atrophy in traumatic optic neuropathy: retrograde neuronal degeneration in humans.

Authors:  Jae Yun Sung; Han Min Lee; Sung Bok Lee; Kyoung Nam Kim; Yeon-Hee Lee
Journal:  Neurol Sci       Date:  2021-07-09       Impact factor: 3.307

  5 in total