Literature DB >> 25478786

Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study.

Jing Shan1, Andrew W Tucker, Yueh Z Lee, Michael D Heath, Xiaohui Wang, David H Foos, Jianping Lu, Otto Zhou.   

Abstract

Chest tomosynthesis is a low-dose, quasi-3D imaging modality that has been demonstrated to improve the detection sensitivity for small lung nodules, compared to 2D chest radiography. The purpose of this study is to investigate the feasibility and system requirements of stationary chest tomosynthesis (s-DCT) using a spatially distributed carbon nanotube (CNT) x-ray source array, where the projection images are collected by electronically activating individual x-ray focal spots in the source array without mechanical motion of the x-ray source, detector, or the patient. A bench-top system was constructed using an existing CNT field emission source array and a flat panel detector. The tube output, beam quality, focal spot size, system in-plane and in-depth resolution were characterized. Tomosynthesis slices of an anthropomorphic chest phantom were reconstructed for image quality assessment. All 75 CNT sources in the source array were shown to operate reliably at 80 kVp and 5 mA tube current. Source-to-source consistency in the tube current and focal spot size was observed. The incident air kerma reading per mAs was measured as 74.47 uGy mAs(-1) at 100 cm. The first half value layer of the beam was 3 mm aluminum. An average focal spot size of 2.5  ×  0.5 mm was measured. The system MTF was measured to be 1.7 cycles mm(-1) along the scanning direction, and 3.4 cycles mm(-1) perpendicular to the scanning direction. As the angular coverage of 11.6°-34°, the full width at half maximum of the artifact spread function improved greatly from 9.5 to 5.2 mm. The reconstructed tomosynthesis slices clearly show airways and pulmonary vascular structures in the anthropomorphic lung phantom. The results show the CNT source array is capable of generating sufficient dose for chest tomosynthesis imaging. The results obtained so far suggest an s-DCT using a distributed CNT x-ray source array is feasible.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25478786     DOI: 10.1088/0031-9155/60/1/81

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  A dual-view digital tomosynthesis imaging technique for improved chest imaging.

Authors:  Yuncheng Zhong; Chao-Jen Lai; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array.

Authors:  J Shan; A W Tucker; L R Gaalaas; G Wu; E Platin; A Mol; J Lu; O Zhou
Journal:  Dentomaxillofac Radiol       Date:  2015-06-19       Impact factor: 2.419

3.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

4.  Simulation on system configuration for stationary head CT using linear carbon nanotube x-ray source arrays.

Authors:  Yueting Luo; Derrek Spronk; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2021-10-20

5.  Characterization and preliminary imaging evaluation of a clinical prototype stationary intraoral tomosynthesis system.

Authors:  Christina R Inscoe; Enrique Platin; Sally M Mauriello; Angela Broome; Andre Mol; Laurence R Gaalaas; Michael W Regan Anderson; Connor Puett; Jianping Lu; Otto Zhou
Journal:  Med Phys       Date:  2018-10-17       Impact factor: 4.071

6.  Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis.

Authors:  Elias Taylor Gunnell; Dora K Franceschi; Christina R Inscoe; Allison Hartman; Jennifer L Goralski; Agathe Ceppe; Brian Handly; Cassandra Sams; Lynn Ansley Fordham; Jianping Lu; Otto Zhou; Yueh Z Lee
Journal:  Eur Radiol       Date:  2018-09-25       Impact factor: 5.315

7.  First-in-Human Study of Acoustic Angiography in the Breast and Peripheral Vasculature.

Authors:  Sarah E Shelton; Brooks D Lindsey; Paul A Dayton; Yueh Z Lee
Journal:  Ultrasound Med Biol       Date:  2017-10-02       Impact factor: 2.998

8.  Modeling of Laser-Induced Plasmon Effects in GNS-DLC-Based Material for Application in X-ray Source Array Sensors.

Authors:  Alexander N Yakunin; Sergey V Zarkov; Yuri A Avetisyan; Garif G Akchurin; Nikolay P Aban'shin; Valery V Tuchin
Journal:  Sensors (Basel)       Date:  2021-02-10       Impact factor: 3.576

9.  Stationary Computed Tomography for Space and other Resource-constrained Environments.

Authors:  Avilash Cramer; Jake Hecla; Dufan Wu; Xiaochun Lai; Tim Boers; Kai Yang; Tim Moulton; Steven Kenyon; Zaven Arzoumanian; Wolfgang Krull; Keith Gendreau; Rajiv Gupta
Journal:  Sci Rep       Date:  2018-09-21       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.