Literature DB >> 25476699

Reducing composite restoration polymerization shrinkage stress through resin modified glass-ionomer based adhesives.

S J Naoum1, P R Mutzelburg1, T G Shumack1, Djg Thode1, F E Martin1, A E Ellakwa1.   

Abstract

BACKGROUND: The aim of this study was to determine whether employing resin modified glass-ionomer based adhesives can reduce polymerization contraction stress generated at the interface of restorative composite adhesive systems.
METHODS: Five resin based adhesives (G Bond, Optibond-All-in-One, Optibond-Solo, Optibond-XTR and Scotchbond-Universal) and two resin modified glass-ionomer based adhesives (Riva Bond-LC, Fuji Bond-LC) were analysed. Each adhesive was applied to bond restorative composite Filtek-Z250 to opposing acrylic rods secured within a universal testing machine. Stress developed at the interface of each adhesive-restorative composite system (n = 5) was calculated at 5-minute intervals over 6 hours.
RESULTS: The resin based adhesive-restorative composite systems (RBA-RCS) demonstrated similar interface stress profiles over 6 hours; initial rapid contraction stress development (0-300 seconds) followed by continued contraction stress development ≤0.02MPa/s (300 seconds - 6 hours). The interface stress profile of the resin modified glass-ionomer based adhesive-restorative composite systems (RMGIBA-RCS) differed substantially to the RBA-RCS in several ways. Firstly, during 0-300 seconds the rate of contraction stress development at the interface of the RMGIBA-RCS was significantly (p < 0.05) lower than at the interface of the RBA-RCS. Secondly, at 300 seconds and 6 hours the interface contraction stress magnitude of the RMGIBA-RCS was significantly (p < 0.05) lower than the stress of all assessed RBA-RCS. Thirdly, from 300 seconds to 6 hours both the magnitude and rate of interface stress of the RMGIBA-RCS continued to decline over the 6 hours from the 300 seconds peak.
CONCLUSIONS: The use of resin modified glass-ionomer based adhesives can significantly reduce the magnitude and rate of polymerization contraction stress developed at the interface of adhesive-restorative composite systems.
© 2015 Australian Dental Association.

Keywords:  Dentine bonding; Riva Bond LC; polymerization shrinkage; resin composite; resin modified glass-ionomer

Mesh:

Substances:

Year:  2015        PMID: 25476699     DOI: 10.1111/adj.12265

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  1 in total

1.  A discussion on how to apply resin-modified glass ionomers.

Authors:  Maryam Khoroushi
Journal:  Contemp Clin Dent       Date:  2016 Jul-Sep
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.