Literature DB >> 25476349

The microwave induced plasma with optical emission spectrometry (MIP-OES) in 23 elements determination in geological samples.

P Niedzielski1, L Kozak2, M Wachelka3, K Jakubowski4, J Wybieralska5.   

Abstract

The article presents the optimisation, validation and application of the microwave induced plasma optical emission spectrometry (MIP-OES) dedicated for a routine determination of Ag, Al, B, Ba, Bi, Ca, Cd, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sr, Tl, Zn, in the geological samples. The three procedures of sample preparation has been proposed: sample digestion with the use of hydrofluoric acid for determination of total concentration of elements, extraction by aqua regia for determination of the quasi-total element concentration and extraction by hydrochloric acid solution to determine contents of the elements in acid leachable fraction. The detection limits were on the level 0.001-0.121 mg L(-1) (from 0.010-0.10 to 1.2-12 mg kg(-1) depend on the samples preparation procedure); the precision: 0.20-1.37%; accuracy 85-115% (for recovery for certified standards materials analysis and parallel analysis by independent analytical techniques: X-ray fluorescence (XRF) and flame absorption spectrometry (FAAS)). The conformity of the results obtained by MIP-OES analytical procedures with the results obtained by XRF and FAAS analysis allows to propose the procedures for studies of elemental composition of the fraction of the geological samples. Additionally, the MIP-OES technique is much less expensive than ICP techniques and much less time-consuming than AAS techniques.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atomic absorption spectrometry; Geological samples; Microwave induced plasma optical emission spectrometry; Multielemental analysis; X-ray fluorescence

Mesh:

Substances:

Year:  2014        PMID: 25476349     DOI: 10.1016/j.talanta.2014.10.009

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Iron's fingerprint of deposits-iron speciation as a geochemical marker.

Authors:  Przemysław Niedzielski; Lidia Kozak
Journal:  Environ Sci Pollut Res Int       Date:  2017-10-13       Impact factor: 4.223

2.  Determination of major elements in igneous rocks using microwave plasma atomic emission spectrometry (MP-AES).

Authors:  María Cecilia Geisenblosen; Pedro Oyhantçabal; Mariela Pistón
Journal:  MethodsX       Date:  2022-07-26
  2 in total