Literature DB >> 25473615

Subacromial spacer placement for protection of rotator cuff repair.

Gregor Szöllösy1, Claudio Rosso2, Simon Fogerty3, Kalojan Petkin3, Laurent Lafosse3.   

Abstract

Rotator cuff repairs have a high failure rate proportional to the tear size. Various techniques have been described to improve the repair strength and failure rate. The described surgical technique uses a biodegradable subacromial balloon-shaped spacer (InSpace; OrthoSpace, Caesarea, Israel) that is implanted arthroscopically to protect our tendon repair. We describe the introduction technique and suggest some hints and tricks. The spacer is placed under direct vision in the subacromial space after the rotator cuff repair is finished. Correct placement is verified by moving the arm freely. The subacromial spacer may help to protect the rotator cuff repair by centering the humeral head and reducing friction between suture knots and the acromion. It may also help to flatten dog-ear formations.

Entities:  

Year:  2014        PMID: 25473615      PMCID: PMC4246409          DOI: 10.1016/j.eats.2014.06.017

Source DB:  PubMed          Journal:  Arthrosc Tech        ISSN: 2212-6287


  8 in total

1.  Arthroscopic biceps tenodesis to supraspinatus tendon: technical note.

Authors:  Laurent Lafosse; Anup A Shah; Robert B Butler; Rachel L Fowler
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2011-07

2.  A new technique to improve tissue grip: "the lasso-loop stitch".

Authors:  Laurent Lafosse; Antoon Van Raebroeckx; Roman Brzoska
Journal:  Arthroscopy       Date:  2006-11       Impact factor: 4.772

3.  Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study.

Authors:  Ignacio Carbonel; Angel Antonio Martinez; Angel Calvo; Jorge Ripalda; Antonio Herrera
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

4.  Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuff tears.

Authors:  Vladimir Senekovic; Boris Poberaj; Ladislav Kovacic; Martin Mikek; Eliyahu Adar; Assaf Dekel
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-12

5.  Supraspinatus tendon load during abduction is dependent on the size of the critical shoulder angle: A biomechanical analysis.

Authors:  Christian Gerber; Jess G Snedeker; Daniel Baumgartner; Arnd F Viehöfer
Journal:  J Orthop Res       Date:  2014-04-04       Impact factor: 3.494

6.  Acromio humeral distance less than six millimeter: its meaning in full-thickness rotator cuff tear.

Authors:  D Goutallier; P Le Guilloux; J-M Postel; C Radier; J Bernageau; S Zilber
Journal:  Orthop Traumatol Surg Res       Date:  2011-04-01       Impact factor: 2.256

7.  [Arthroscopic repair of full-thickness cuff tears: a multicentric retrospective study of 576 cases with anatomical assessment].

Authors:  P-H Flurin; P Landreau; T Gregory; P Boileau; N Brassart; O Courage; E Dagher; N Graveleau; S Guillo; J-F Kempf; L Lafosse; E Laprelle; B Toussaint
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-12

8.  Structural changes of the rotator cuff caused by experimental subacromial impingement in the rat.

Authors:  A G Schneeberger; R W Nyffeler; C Gerber
Journal:  J Shoulder Elbow Surg       Date:  1998 Jul-Aug       Impact factor: 3.019

  8 in total
  10 in total

1.  Early promising outcome following arthroscopic implantation of the subacromial balloon spacer for treating massive rotator cuff tear.

Authors:  R S M Piekaar; I C E Bouman; P M van Kampen; F van Eijk; P E Huijsmans
Journal:  Musculoskelet Surg       Date:  2017-11-18

2.  Subacromial balloon spacer - Where are we now?

Authors:  Aparna Viswanath; Steve Drew
Journal:  J Clin Orthop Trauma       Date:  2021-03-26

3.  Biodegradable balloon spacer for massive irreparable rotator cuff tears is associated with improved functional outcomes, low revisions, and complications rate at minimum one year follow-up.

Authors:  Eran Maman; Efi Kazum; Joseph A Abboud; Yarden Zinger; Shai Factor; Ofir Chechik; Oleg Dolkart
Journal:  Int Orthop       Date:  2022-02-03       Impact factor: 3.075

4.  Comparing Clinical Outcomes After Subacromial Spacer Insertion Versus Other Reconstruction Methods in the Treatment of Irreparable Massive Rotator Cuff Tears.

Authors:  Joo Han Oh; Joo Hyun Park; Hyeon Jang Jeong; Sung-Min Rhee
Journal:  Orthop J Sports Med       Date:  2019-09-25

5.  Protocol for a randomised controlled trial of Subacromial spacer for Tears Affecting Rotator cuff Tendons: a Randomised, Efficient, Adaptive Clinical Trial in Surgery (START:REACTS).

Authors:  Andrew Metcalfe; Elke Gemperle Mannion; Helen Parsons; Jaclyn Brown; Nicholas Parsons; Josephine Fox; Rebecca Kearney; Tom Lawrence; Howard Bush; Kerri McGowan; Iftekhar Khan; James Mason; Charles Hutchinson; Simon Gates; Nigel Stallard; Martin Underwood; Stephen Drew
Journal:  BMJ Open       Date:  2020-05-21       Impact factor: 2.692

6.  The use of a subacromial spacer-inspace balloon in managing patients with irreparable rotator cuff tears.

Authors:  Rahi Kiran Yallapragada; Alex Apostolopoulos; I Katsougrakis; T P Selvan
Journal:  J Orthop       Date:  2018-08-16

7.  Biceps Tenotomy Does not Affect the Functional Outcomes of Patients Treated with Spacer Implantation Due to Massive Irreparable Rotator Cuff Tears.

Authors:  Eran Maman; Ori Safran; Shaul Beyth; Gavriel Mozes; Assaf Dekel; Bernstein Michael; Ofir Chechik; Eliyahu Adar
Journal:  Open Orthop J       Date:  2017-12-29

8.  Subacromial spacer implantation for massive rotator cuff tears: Clinical outcome of arthroscopically treated patients.

Authors:  Malte Holschen; Florian Brand; Jens D Agneskirchner
Journal:  Obere Extrem       Date:  2016-12-01

Review 9.  Outcomes of Subacromial Balloon Spacer Implantation for Massive and Irreparable Rotator Cuff Tears: A Systematic Review.

Authors:  Russell K Stewart; Lisa Kaplin; Stephen A Parada; Benjamin R Graves; Nikhil N Verma; Brian R Waterman
Journal:  Orthop J Sports Med       Date:  2019-10-15

10.  Effect of Ethylene Oxide and Gamma (γ-) Sterilization on the Properties of a PLCL Polymer Material in Balloon Implants.

Authors:  Moran Haim Zada; Awanish Kumar; Omar Elmalak; Guy Mechrez; Abraham J Domb
Journal:  ACS Omega       Date:  2019-12-03
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.