Literature DB >> 25472824

Single centre experience of hypothermic machine perfusion of kidneys from extended criteria deceased heart-beating donors: a comparative study.

J C Forde1,2, W P Shields3, M Azhar3, P J Daly3, J A Zimmermann3, G P Smyth3, M P Eng3, R E Power3, P Mohan3, D P Hickey3, D M Little3.   

Abstract

INTRODUCTION: Kidneys from extended criteria donors are associated with higher rates of delayed graft function (DGF). Hypothermic machine perfusion (MP) for storage is associated with more favourable outcomes.
METHODS: A retrospective analysis was performed in 93 patients where the kidney was stored using hypothermic MP (LifePort(®)) and compared to an age-matched control group where the kidney was stored in cold static storage (CSS) using University of Wisconsin solution.
RESULTS: Median age was similar in both groups (59.2 years in MP vs 59.9 years in CSS, p = 0.5598). Mean cold storage time was 15.6 h in MP vs 17.9 h in CSS. Post transplant mean serum creatinine was as follows; MP group-144.7 μmol/L at 1 month; 138.3 μmol/L at 3 months and 129.5 μmol/L at 12 months. In the CSS group-163 μmol/L at 1 month; 154.9 μmol/L at 3 months and 140.2 μmol/L at 12 months. There was a statistically significant difference at 1 month (p = 0.0096) and 3 months (p = 0.0236). DGF was defined as the need for haemodialysis within 7 days post transplant. In the MP group, DGF occurred in 17.2 % patients with mean of 6 days (range 1-18). In the CSS group, 25.8 % patients with mean of 8.1 days (range 3-25). One-year graft survival rate was better in the MP group (97.85 vs 96.77 %).
CONCLUSION: Our experience to date recommends the use of hypothermic MP for storage of kidneys from extended criteria deceased heart-beating donors.

Entities:  

Keywords:  Extended criteria donor; Hypothermic machine perfusion; Kidney transplant; Outcome

Mesh:

Substances:

Year:  2014        PMID: 25472824     DOI: 10.1007/s11845-014-1235-8

Source DB:  PubMed          Journal:  Ir J Med Sci        ISSN: 0021-1265            Impact factor:   1.568


  25 in total

1.  Is it safe to use a kidney from an expanded criteria donor?

Authors:  J M Kim; S J Kim; J-W Joh; C H D Kwon; S Song; M Shin; B N Kim; S-K Lee
Journal:  Transplant Proc       Date:  2011 Jul-Aug       Impact factor: 1.066

2.  Application of machine perfusion preservation as a viability test for marginal kidney graft.

Authors:  Naoto Matsuno; Osamu Konno; Abudushukur Mejit; Yoshimaro Jyojima; Isao Akashi; Yuki Nakamura; Hitoshi Iwamoto; Koichiro Hama; Toru Iwahori; Tatsuhito Ashizawa; Takeshi Nagao
Journal:  Transplantation       Date:  2006-12-15       Impact factor: 4.939

Review 3.  Marked variation in the definition and diagnosis of delayed graft function: a systematic review.

Authors:  Sri G Yarlagadda; Steven G Coca; Amit X Garg; Mona Doshi; Emilio Poggio; Richard J Marcus; Chirag R Parikh
Journal:  Nephrol Dial Transplant       Date:  2008-04-11       Impact factor: 5.992

4.  Machine perfusion preservation for kidney grafts with a high creatinine from uncontrolled donation after cardiac death.

Authors:  N Matsuno; Y N O Konno; Y Jyojima; I Akashi; H Iwamoto; K Hama; T Hiirano; T Nagao
Journal:  Transplant Proc       Date:  2010 Jan-Feb       Impact factor: 1.066

5.  Economic impact of the introduction of machine perfusion preservation in a kidney transplantation program in the expanded donor era: cost-effectiveness assessment.

Authors:  V Gómez; C Galeano; V Diez; C Bueno; F Díaz; F J Burgos
Journal:  Transplant Proc       Date:  2012-11       Impact factor: 1.066

6.  Survival in recipients of marginal cadaveric donor kidneys compared with other recipients and wait-listed transplant candidates.

Authors:  Akinlolu O Ojo; Julie A Hanson; Herwig-Ulf Meier-Kriesche; Chike N Okechukwu; Robert A Wolfe; Alan B Leichtman; Lawrence Y Agodoa; Bruce Kaplan; Friedrich K Port
Journal:  J Am Soc Nephrol       Date:  2001-03       Impact factor: 10.121

7.  Donor characteristics associated with reduced graft survival: an approach to expanding the pool of kidney donors.

Authors:  Friedrich K Port; Jennifer L Bragg-Gresham; Robert A Metzger; Dawn M Dykstra; Brenda W Gillespie; Eric W Young; Francis L Delmonico; James J Wynn; Robert M Merion; Robert A Wolfe; Philip J Held
Journal:  Transplantation       Date:  2002-11-15       Impact factor: 4.939

8.  Machine perfusion or cold storage in deceased-donor kidney transplantation.

Authors:  Cyril Moers; Jacqueline M Smits; Mark-Hugo J Maathuis; Jürgen Treckmann; Frank van Gelder; Bogdan P Napieralski; Margitta van Kasterop-Kutz; Jaap J Homan van der Heide; Jean-Paul Squifflet; Ernest van Heurn; Günter R Kirste; Axel Rahmel; Henri G D Leuvenink; Andreas Paul; Jacques Pirenne; Rutger J Ploeg
Journal:  N Engl J Med       Date:  2009-01-01       Impact factor: 91.245

Review 9.  A systematic review of kidney transplantation from expanded criteria donors.

Authors:  Julio Pascual; Javier Zamora; John D Pirsch
Journal:  Am J Kidney Dis       Date:  2008-09       Impact factor: 8.860

10.  Reduced expression of inflammatory genes in deceased donor kidneys undergoing pulsatile pump preservation.

Authors:  Valeria R Mas; Kellie J Archer; Catherine I Dumur; Mariano J Scian; Jihee L Suh; Anne L King; Megan E Wardius; Julie A Straub; Marc P Posner; Kenneth Brayman; Daniel G Maluf
Journal:  PLoS One       Date:  2012-04-24       Impact factor: 3.240

View more
  2 in total

Review 1.  Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis.

Authors:  Ahmer M Hameed; Henry C Pleass; Germaine Wong; Wayne J Hawthorne
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

Review 2.  Machine Perfusion for Abdominal Organ Preservation: A Systematic Review of Kidney and Liver Human Grafts.

Authors:  Maria Irene Bellini; Mikhail Nozdrin; Janice Yiu; Vassilios Papalois
Journal:  J Clin Med       Date:  2019-08-15       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.