Microdamage generation by tapered and cylindrical mini-screw implants after pilot drilling.

Emily Taing-Watson1, Thomas R Katona2, Kelton T Stewart3, Ahmed Ghoneima3, Gabriel T M Chu4, Hee-Moon Kyung5, Sean S Liu3.   

Abstract

OBJECTIVE: To investigate the relationship between mini-screw implant (MSI) diameter (1.6 vs 2.0 mm) and shape (tapered vs cylindrical) and the amount of microdamage generated during insertion.
MATERIALS AND METHODS: Thirty-six cylindrical and 36 tapered MSIs, 6 mm long, were used in this study. Half of each shape was 1.6 mm in diameter, while the other half was 2.0 mm. After pilot drilling, four and five MSIs were inserted, respectively, into fresh cadaveric maxillae and mandibles of dogs. Bone blocks containing the MSIs were sectioned and ground parallel to the MSI axis. Epifluorescent microscopy was used to measure overall cortical thickness, crack length, and crack number adjacent to the MSI. Crack density and total microdamage burden per surface length were calculated. Three-way analysis of variance (ANOVA) was used to test the effects of jaw, and MSI shape and diameter. Pairwise comparisons were made to control the overall significance level at 5%.
RESULTS: The larger (2.0 vs 1.6 mm) cylindrical MSIs increased the numbers, lengths, and densities of microcracks, and the total microdamage burden. The same diameter cylindrical and tapered MSIs generated a similar number of cracks and crack lengths. More total microdamage burden was created by the 2.0-mm cylindrical than the 2.0-mm tapered MSIs. Although higher crack densities were produced by the insertion of 1.6-mm tapered MSIs, there was no difference in total microdamage burden induced by 1.6-mm tapered and 1.6-mm cylindrical MSIs.
CONCLUSIONS: Pilot drilling is effective in reducing microdamage during insertion of tapered MSIs. To prevent excessive microdamage, large diameter and cylindrical MSIs should be avoided.

Entities:  

Keywords:  Cylindrical; Microdamage; Mini-screw implants; Tapered

Mesh:

Substances:

Year:  2014        PMID: 25469670     DOI: 10.2319/062314-452.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  2 in total

1.  Histomorphometric analysis of microcrack healing after the installation of mini-implants.

Authors:  Soobin Shin; Pan-Soo Park; Seung-Hak Baek; Il-Hyung Yang
Journal:  J Periodontal Implant Sci       Date:  2015-04-29       Impact factor: 2.614

Review 2.  Revisiting the Complications of Orthodontic Miniscrew.

Authors:  Van Mai Truong; Soyeon Kim; Jaeheon Kim; Joo Won Lee; Young-Seok Park
Journal:  Biomed Res Int       Date:  2022-08-01       Impact factor: 3.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.