Simultaneous determination of seven β2-agonists in human and bovine urine by isotope dilution liquid chromatography-tandem mass spectrometry using compound-specific minimally 13C-labelled analogues.

Ana González-Antuña1, Pablo Rodríguez-González2, Giuseppe Centineo3, J Ignacio García Alonso1.   

Abstract

Seven β2-agonist (clenproperol, clenbuterol, salbutamol, bronbuterol, ractopamine, clenpenterol and clencyclohexerol) were determined simultaneously in human and bovine urine by isotope dilution LC-ESI-MS/MS in a triple quadrupole instrument. The method is based on the application of multiple linear regression in combination with compound-specific minimally 13C-labelled analogues. Additionally, the increase of the bandpass of the first quadrupole during the selected reaction monitoring (SRM) measurement procedure allowed the simultaneous quantification of the seven compounds at sub ngg-1 levels in a single chromatogram without resorting to a methodological calibration graph. Recovery values at concentration levels between 5.0 and 0.05ngg-1 ranged from 95 to 110% in fortified bovine urine and from 91 to 108% in human urine, with relative standard deviations lower than 5% except for salbutamol and ractopamine. The proposed methodology was validated by analyzing the certified reference material BCR-503 (lyophilized bovine urine) certified for clenbuterol and salbutamol. The limits of detection (LOD) for a sample volume of 10mL of both human and bovine urine was found to be lower than 0.012ngg-1 for all compounds, except to salbutamol in bovine urine which was of 0.029ngg-1. The use of compound-specific isotopically labelled analogues minimally labelled in 13C minimized the occurrence of isotope effects and corrected for matrix effects during ESI ionization and can be efficiently applied for the quantification of ultra-trace concentrations of β2-agonists in human and bovine urine.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Isotope dilution; Liquid chromatography; Matrix effects; Minimal labeling; Selected reaction monitoring; Tandem mass spectrometry

Year:  2014        PMID: 25468499     DOI: 10.1016/j.chroma.2014.10.065

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Isotope pattern deconvolution as a successful alternative to calibration curve for application in wastewater-based epidemiology.

Authors:  Jorge Pitarch-Motellón; Lubertus Bijlsma; Juan Vicente Sancho Llopis; Antoni F Roig-Navarro
Journal:  Anal Bioanal Chem       Date:  2021-03-17       Impact factor: 4.142

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.