Literature DB >> 25462527

To what extent can cortical bone millimeter-scale elasticity be predicted by a two-phase composite model with variable porosity?

Mathilde Granke1, Quentin Grimal2, William J Parnell3, Kay Raum4, Alf Gerisch5, Françoise Peyrin6, Amena Saïed2, Pascal Laugier2.   

Abstract

An evidence gap exists in fully understanding and reliably modeling the variations in elastic anisotropy that are observed at the millimeter scale in human cortical bone. The porosity (pore volume fraction) is known to account for a large part, but not all, of the elasticity variations. This effect may be modeled by a two-phase micromechanical model consisting of a homogeneous matrix pervaded by cylindrical pores. Although this model has been widely used, it lacks experimental validation. The aim of the present work is to revisit experimental data (elastic coefficients, porosity) previously obtained from 21 cortical bone specimens from the femoral mid-diaphysis of 10 donors and test the validity of the model by proposing a detailed discussion of its hypotheses. This includes investigating to what extent the experimental uncertainties, pore network modeling, and matrix elastic properties influence the model's predictions. The results support the validity of the two-phase model of cortical bone which assumes that the essential source of variations of elastic properties at the millimeter-scale is the volume fraction of vascular porosity. We propose that the bulk of the remaining discrepancies between predicted stiffness coefficients and experimental data (RMSE between 6% and 9%) is in part due to experimental errors and part due to small variations of the extravascular matrix properties. More significantly, although most of the models that have been proposed for cortical bone were based on several homogenization steps and a large number of variable parameters, we show that a model with a single parameter, namely the volume fraction of vascular porosity, is a suitable representation for cortical bone. The results could provide a guide to build specimen-specific cortical bone models. This will be of interest to analyze the structure-function relationship in bone and to design bone-mimicking materials.
Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anisotropic elasticity; Cortical bone; Effective properties; Mechanical model; Porosity

Mesh:

Year:  2014        PMID: 25462527     DOI: 10.1016/j.actbio.2014.10.011

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  3 in total

1.  Microstructure, mineral and mechanical properties of teleost intermuscular bones.

Authors:  I A K Fiedler; S Zeveleva; A Duarte; X Zhao; B Depalle; L Cardoso; S Jin; J P Berteau
Journal:  J Biomech       Date:  2019-07-17       Impact factor: 2.712

2.  Towards assessing cortical bone porosity using low-frequency quantitative acoustics: A phantom-based study.

Authors:  Florian Vogl; Benjamin Bernet; Daniele Bolognesi; William R Taylor
Journal:  PLoS One       Date:  2017-09-07       Impact factor: 3.240

3.  Measuring bone stiffness using spherical indentation.

Authors:  Oliver R Boughton; Shaocheng Ma; Sarah Zhao; Matthew Arnold; Angus Lewis; Ulrich Hansen; Justin P Cobb; Finn Giuliani; Richard L Abel
Journal:  PLoS One       Date:  2018-07-12       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.