Literature DB >> 25460894

Immunoassay of paralytic shellfish toxins by moving magnetic particles in a stationary liquid-phase lab-on-a-chip.

Myoung-Ho Kim1, Suk-Jung Choi2.   

Abstract

In this study, we devised a stationary liquid-phase lab-on-a-chip (SLP LOC), which was operated by moving solid-phase magnetic particles in the stationary liquid phase. The SLP LOC consisted of a sample chamber to which a sample and reactants were added, a detection chamber containing enzyme substrate solution, and a narrow channel connecting the two chambers and filled with buffer. As a model system, competitive immunoassays of saxitoxin (STX), a paralytic shellfish toxin, were conducted in the SLP LOC using protein G-coupled magnetic particles (G-MPs) as the solid phase. Anti-STX antibodies, STX-horseradish peroxidase conjugate, G-MPs, and a STX sample were added to the sample chamber and reacted by shaking. While liquids were in the stationary state, G-MPs were transported from the sample chamber to the detection chamber by moving a magnet below the LOC. After incubation to allow the enzymatic reaction to occur, the absorbance of the detection chamber solution was found to be reciprocally related to the STX concentration of the sample. Thus, the SLP LOC may represent a novel, simple format for point-of-care testing applications of enzyme-linked immunosorbent assays by eliminating complicated liquid handling steps.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Enzyme-linked immunosorbent assay; Lab-on-a-chip; Magnetic particle; Paralytic shellfish toxin; Stationary liquid phase

Mesh:

Substances:

Year:  2014        PMID: 25460894     DOI: 10.1016/j.bios.2014.11.012

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Nominal effective immunoreaction volume of magnetic beads at single bead level.

Authors:  Rui Wang; Yuan Chen; Kai Fan; Feng Ji; Jian Wu; Yong-Hua Yu
Journal:  J Zhejiang Univ Sci B       Date:  2017 Oct.       Impact factor: 3.066

2.  Integrating scFv into xMAP Assays for the Detection of Marine Toxins.

Authors:  Lisa C Shriver-Lake; Jinny L Liu; P Audrey Brozozog Lee; Ellen R Goldman; Richard Dietrich; Erwin Märtlbauer; George P Anderson
Journal:  Toxins (Basel)       Date:  2016-11-21       Impact factor: 4.546

3.  A simple electrochemical aptasensor for saxitoxin detection.

Authors:  Weixian Zheng; Xinyu Liu; Qianwen Li; Zuju Shu; Zhongbo Li; Lijun Zhang
Journal:  RSC Adv       Date:  2022-08-23       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.