Literature DB >> 25460880

PolyA-tailed and fluorophore-labeled aptamer-gold nanoparticle conjugate for fluorescence turn-on bioassay using iodide-induced ligand displacement.

Wei Li1, Yifan Dong1, Xi Wang1, Hui Li1, Danke Xu2.   

Abstract

Depending on the strong affinity of polyA sequence to gold (or silver) surface, applicability of polyA-tailed DNA-gold (or silver) nanoparticle conjugates in homogeneous and heterogeneous protein assays was first demonstrated. Interestingly, when using polyA-tailed, fluophore-labeled DNA-AuNP conjugate, it was found that iodide and thiosulfate anions could act as the ligand displacing reagent to detach polyA-tailed DNA strands from AuNP surface and simultaneously activate the AuNP-quenched fluorophores by destroying the polyA-AuNP interaction via a divide-and-conquer strategy. Based on this new discovery, we have developed a novel, cost-effective and sandwich-type fluorescence turn-on aptasensor for highly sensitive and specific thrombin detection, what took advantage of aptamer-conjugated magnetic beads (apt-MBs) for protein capture and separation, and iodide-induced fluorescence recovery of activatable polyA-based AuNP probes through ligand displacement for fluorescence turn-on detection. This proposed aptasensor could detect thrombin specifically with a detection limit as low as 89pM, which was better than or comparable to many existing fluorescent thrombin assays. Importantly, employment of such polyA-based AuNP conjugate not only avoids the use of thiolated oligonucleotides and thiol-containing displacing reagents, but also offers new possibilities for fabricating convenient and cost-effective bioanalytical applications.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluorescence; Gold nanoparticles; Iodide; Ligand displacement; PolyA-tailed aptamer; Thrombin aptasensor

Mesh:

Substances:

Year:  2014        PMID: 25460880     DOI: 10.1016/j.bios.2014.10.047

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A multi-channel localized surface plasmon resonance system for absorptiometric determination of abscisic acid by using gold nanoparticles functionalized with a polyadenine-tailed aptamer.

Authors:  Shun Wang; Hao Zhang; Wei Li; Zephania Birech; Liuzheng Ma; Dongxian Li; Shixin Li; Ling Wang; Junjuan Shang; Jiandong Hu
Journal:  Mikrochim Acta       Date:  2019-12-05       Impact factor: 5.833

2.  A Novel Fluorescent Biosensor for Adenosine Triphosphate Detection Based on a Metal⁻Organic Framework Coating Polydopamine Layer.

Authors:  Peipei Xu; Guangfu Liao
Journal:  Materials (Basel)       Date:  2018-09-05       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.