Literature DB >> 25459923

Flow-through enzyme immobilized amperometric detector for the rapid screening of acetylcholinesterase inhibitors by flow injection analysis.

Marie Vandeput1, Cobra Parsajoo2, Jérôme Vanheuverzwijn2, Stéphanie Patris2, Yavuz Yardim3, Alexandre le Jeune2, Ahmad Sarakbi2, Dominique Mertens2, Jean-Michel Kauffmann4.   

Abstract

A commercially available thin-layer flow-through amperometric detector, with the sensing block customized in an original design, was applied to the screening of drug compounds known as acetylcholinesterase (AChE) inhibitors. AChE from electric eel was covalently immobilized onto a cysteamine modified gold disk adjacent to a silver disk working electrode. On-line studies were performed by flow injection analysis (FIA) in PBS buffer pH 7.4. Seven commercially available AChE inhibitors used in the medical field, namely neostigmine, eserine, tacrine, donepezil, rivastigmine, pyridostigmine and galantamine as well as two natural compounds, quercetin and berberine, were investigated. The same trend of inhibitory potency as described in the literature was observed. Of particular interest and in addition to the determination of the IC50 values, this flow-through system allowed the study of both, the stability of the enzyme-inhibitor complex and the kinetic of the enzyme activity recovery.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acetylcholinesterase; Drug screening; Enzyme inhibition; FIA; Silver electrode

Mesh:

Substances:

Year:  2014        PMID: 25459923     DOI: 10.1016/j.jpba.2014.09.012

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

Review 1.  Recent Advances in Electrochemical Biosensors Based on Enzyme Inhibition for Clinical and Pharmaceutical Applications.

Authors:  Loubna El Harrad; Ilhame Bourais; Hasna Mohammadi; Aziz Amine
Journal:  Sensors (Basel)       Date:  2018-01-09       Impact factor: 3.576

2.  MAPLE Assembled Acetylcholinesterase⁻Polyethylenimine Hybrid and Multilayered Interfaces for Toxic Gases Detection.

Authors:  Valentina Dinca; Cristian Viespe; Simona Brajnicov; Izabela Constantinoiu; Antoniu Moldovan; Anca Bonciu; Constantin Nicolae Toader; Raluca Elena Ginghina; Nicoleta Grigoriu; Maria Dinescu; Nicu Doinel Scarisoreanu
Journal:  Sensors (Basel)       Date:  2018-12-04       Impact factor: 3.576

3.  Love Wave Surface Acoustic Wave Sensor with Laser-Deposited Nanoporous Gold Sensitive Layer.

Authors:  Cristian Viespe; Valentina Dinca; Gianina Popescu-Pelin; Dana Miu
Journal:  Sensors (Basel)       Date:  2019-10-16       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.