Literature DB >> 25459060

A reusable robust radio frequency biosensor using microwave resonator by integrated passive device technology for quantitative detection of glucose level.

N Y Kim1, R Dhakal2, K K Adhikari3, E S Kim3, C Wang3.   

Abstract

A reusable robust radio frequency (RF) biosensor with a rectangular meandered line (RML) resonator on a gallium arsenide substrate by integrated passive device (IPD) technology was designed, fabricated and tested to enable the real-time identification of the glucose level in human serum. The air-bridge structure fabricated by an IPD technology was applied to the RML resonator to improve its sensitivity by increasing the magnitude of the return loss (S21). The resonance behaviour, based on S21 characteristics of the biosensor, was analysed at 9.20 GHz with human serum containing different glucose concentration ranging from 148-268 mg dl(-1), 105-225 mg dl(-1) and at a deionised (D) water glucose concentration in the range of 25- 500 mg dl(-1) for seven different samples. A calibration analysis was performed for the human serum from two different subjects and for D-glucose at a response time of 60 s; the reproducibility, the minimum shift in resonance frequency and the long-term stability of the signal were investigated. The feature characteristics based on the resonance concept after the use of serum as an analyte are modelled as an inductor, capacitor and resistor. The findings support the development of resonance-based sensing with an excellent sensitivity of 1.08 MHz per 1 mg dl(-1), a detection limit of 8.01 mg dl(-1), and a limit of quantisation of 24.30 mg dl(-1).
Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Glucose sensor; Integrated passive device; Microwave sensing; RF biosensor; Real-time identification; Reusable biosensor

Mesh:

Substances:

Year:  2014        PMID: 25459060     DOI: 10.1016/j.bios.2014.10.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  20 in total

Review 1.  Capacitive Biosensors and Molecularly Imprinted Electrodes.

Authors:  Gizem Ertürk; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-02-17       Impact factor: 3.576

2.  Fabrication of QFN-Packaged Miniaturized GaAs-Based Bandpass Filter with Intertwined Inductors and Dendritic Capacitor.

Authors:  Jian Chen; Zhi-Ji Wang; Bao-Hua Zhu; Eun-Seong Kim; Nam-Young Kim
Journal:  Materials (Basel)       Date:  2020-04-20       Impact factor: 3.623

3.  Micro-Fabricated Resonator Based on Inscribing a Meandered-Line Coupling Capacitor in an Air-Bridged Circular Spiral Inductor.

Authors:  Eun Seong Kim; Nam Young Kim
Journal:  Micromachines (Basel)       Date:  2018-06-12       Impact factor: 2.891

4.  Rapid and real-time monitoring of bacterial growth against antibiotics in solid growth medium using a contactless planar microwave resonator sensor.

Authors:  Mandeep Chhajer Jain; Anupama Vijaya Nadaraja; Rakesh Narang; Mohammad Hossein Zarifi
Journal:  Sci Rep       Date:  2021-07-20       Impact factor: 4.379

5.  A Non-Invasive Phase Sensor for Permittivity and Moisture Estimation Based on Anomalous Dispersion.

Authors:  Omar Siddiqui; Rashad Ramzan; Muhammad Amin; Omar M Ramahi
Journal:  Sci Rep       Date:  2016-06-27       Impact factor: 4.379

Review 6.  Early Diagnosis of Breast Cancer.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2017-07-05       Impact factor: 3.576

7.  Glucose Sensing Using Capacitive Biosensor Based on Polyvinylidene Fluoride Thin Film.

Authors:  Ambran Hartono; Edi Sanjaya; Ramli Ramli
Journal:  Biosensors (Basel)       Date:  2018-01-30

8.  Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor.

Authors:  Gyan Raj Koirala; Rajendra Dhakal; Eun-Seong Kim; Zhao Yao; Nam-Young Kim
Journal:  Sensors (Basel)       Date:  2018-04-03       Impact factor: 3.576

9.  High-Sensitivity, Quantified, Linear and Mediator-Free Resonator-Based Microwave Biosensor for Glucose Detection.

Authors:  Alok Kumar; Cong Wang; Fan-Yi Meng; Zhong-Liang Zhou; Meng Zhao; Guo-Feng Yan; Eun-Seong Kim; Nam-Young Kim
Journal:  Sensors (Basel)       Date:  2020-07-20       Impact factor: 3.576

10.  Sensitive, Real-time and Non-Intrusive Detection of Concentration and Growth of Pathogenic Bacteria using Microfluidic-Microwave Ring Resonator Biosensor.

Authors:  Rakesh Narang; Sevda Mohammadi; Mehdi Mohammadi Ashani; Hamid Sadabadi; Hossein Hejazi; Mohammad Hossein Zarifi; Amir Sanati-Nezhad
Journal:  Sci Rep       Date:  2018-10-25       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.