Literature DB >> 25459055

Magnetic bead droplet immunoassay of oligomer amyloid β for the diagnosis of Alzheimer's disease using micro-pillars to enhance the stability of the oil-water interface.

Jeong Ah Kim1, Moojong Kim1, Sung Min Kang2, Kun Taek Lim2, Tae Song Kim1, Ji Yoon Kang3.   

Abstract

Despite scientific progress in the study of Alzheimer's disease (AD), it is still challenging to develop a robust and sensitive methodology for the early diagnosis of AD due to the lack of a decisive biomarker in blood. Recent reports on the oligomer amyloid β (Aβ) as a biomarker demonstrated its possibility for identifying early onset of AD in patients, but its low concentration in blood requires highly reliable detection techniques. To overcome the low reliability and labor-intensive procedures of conventional enzyme-linked immunosorbent assay (ELISA), we present a magnetic bead-droplet immunoassay platform for simple and highly sensitive detection of oligomer Aβ for the diagnosis of AD. This microchip consists of chambers that contain water-based reagents or oil for consecutive assay procedures, and there are arrays of micro-pillars fabricated between the two adjacent chambers to form robust water-oil interfaces. With the aid of these micro-pillars, magnetic beads can stably pass through each chamber by linearly actuating a magnet along the microchip. The robust water-oil interface and simple procedures of the assay make it possible to obtain reliable results from this microchip. The intensity of the fluorescence at the read-out chamber increased quantitatively and linearly, depending on the amount of serially-diluted standard Aβ solution. The results of the assay indicated that the limit of detection was about 10 pg/mL even though it was done with manual manipulation of the magnet. This platform simplified the complicated ELISA procedure and achieved high sensitivity that was no lower than that of the conventional magnetic bead immunoassay. The magnetic bead-droplet platform reduced the assay time to 45 min, and it also reduced the amount of antibody usage in a single diagnosis significantly (10-30 ng of antibody per single assay). Consequently, this microfluidic chip has strong potential as a feasible system for use in the diagnosis of AD with a fast and easy immunoassay process, since the suggested platform can be automated with ease for point-of-care testing as well as high-throughput diagnostic equipment.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alzheimer′s disease; Amyloid β (Aβ); Enzyme-linked immunosorbent assay (ELISA); Magnetic bead; Magnetic droplet

Mesh:

Substances:

Year:  2014        PMID: 25459055     DOI: 10.1016/j.bios.2014.10.042

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Magnetic actuation and deformation of a soft shuttle.

Authors:  Ana Daysi Ruvalcaba-Cardenas; Raul Alejandro Ramirez Gomez; Khashayar Khoshmanesh; Francisco J Tovar-Lopez
Journal:  Biomicrofluidics       Date:  2020-05-18       Impact factor: 2.800

2.  An electrochemical aptasensor for amyloid-β oligomer based on double-stranded DNA as "conductive spring".

Authors:  Chunyan Deng; Hui Liu; Shihui Si; Xiaojun Zhu; Qiuyun Tu; Yan Jin; Juan Xiang
Journal:  Mikrochim Acta       Date:  2020-03-18       Impact factor: 5.833

3.  Fabrication of an antibody-aptamer sandwich assay for electrochemical evaluation of levels of β-amyloid oligomers.

Authors:  Yanli Zhou; Huanqing Zhang; Lantao Liu; Congming Li; Zhu Chang; Xu Zhu; Baoxian Ye; Maotian Xu
Journal:  Sci Rep       Date:  2016-10-11       Impact factor: 4.379

4.  A sensitive and selective electrochemical biosensor for the determination of beta-amyloid oligomer by inhibiting the peptide-triggered in situ assembly of silver nanoparticles.

Authors:  Yun Xing; Xiao-Zhen Feng; Lipeng Zhang; Jiating Hou; Guo-Cheng Han; Zhencheng Chen
Journal:  Int J Nanomedicine       Date:  2017-04-18

5.  Bead mediated separation of microparticles in droplets.

Authors:  Sida Wang; Ki-Joo Sung; Xiaoxia Nina Lin; Mark A Burns
Journal:  PLoS One       Date:  2017-03-10       Impact factor: 3.240

6.  Detection of anti-p53 autoantibodies in saliva using microfluidic chips for the rapid screening of oral cancer.

Authors:  Yen-Heng Lin; Chih-Ching Wu; Yong-Sheng Peng; Chia-Wei Wu; Ya-Ting Chang; Kai-Ping Chang
Journal:  RSC Adv       Date:  2018-04-24       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.