Literature DB >> 25457330

Incidence of donor site morbidity following harvesting from iliac crest or RIA graft.

G M Calori1, M Colombo2, E L Mazza2, S Mazzola2, E Malagoli2, G V Mineo3.   

Abstract

INTRODUCTION: Clinical management of non-union of long bone fractures and segmental bone defect is a challenge for orthopaedic surgeons. The use of autologous bone graft (ABG) is always considered the gold standard treatment. Traditional techniques for harvesting ABG from iliac crest usually involve several complications, particularly at the donor site. The Reamer-Irrigator-Aspirator (RIA) is an intramedullary reaming system that generates a large volume of cancellous bone material in a single-step reaming process; this bone material can be collected and potentially used as an ABG source. Our interest is to compare the complications associated with the standard technique of harvesting from iliac crest with those of the innovative RIA harvesting device.
MATERIALS AND METHODS: A database of 70 patients with long bone non-unions was studied. The patients were divided into two groups according to the surgical harvesting technique used: RIA system ABG (35 patients) and iliac crest ABG (35 patients).
RESULTS: At the 12-month follow-up, pain at the donor site was reported in no patients in the RIA system ABG group and five of 35 patients (14.28%) in the iliac crest ABG group. Local infections at the donor site were found in no patients in the RIA system ABG group compared with five patients (14.28%) in the iliac crest ABG group. There were no fractures in the RIA system ABG group and one case (2.85%) of anterior superior iliac spine (ASIS) dislocation in the iliac crest ABG group. No systemic infections were detected in either group. DISCUSSION: We analysed the scientific literature on the use of RIA technique to collect ABG for use in patients with anthropic-oligotrophic non-unions, with a focus on the complications associated with this technique.
CONCLUSION: RIA bone graft for the treatment of non-unions and segmental bone defect of long bones seems to be a safe and efficient procedure with low donor site morbidity.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone defect; Bone graft; Diamond concept; Iliac crest; Non-union; Polytherapy; RIA; Reamer irrigator aspirator; Segmental defect

Mesh:

Year:  2014        PMID: 25457330     DOI: 10.1016/j.injury.2014.10.034

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  35 in total

1.  3D Printed Vascular Networks Enhance Viability in High-Volume Perfusion Bioreactor.

Authors:  Owen Ball; Bao-Ngoc B Nguyen; Jesse K Placone; John P Fisher
Journal:  Ann Biomed Eng       Date:  2016-06-06       Impact factor: 3.934

Review 2.  [Reconstruction of osseous defects using the Masquelet technique].

Authors:  F Saxer; H Eckardt
Journal:  Orthopade       Date:  2017-08       Impact factor: 1.087

Review 3.  Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

Authors:  Markus Rupp; Christoph Biehl; Matthäus Budak; Ulrich Thormann; Christian Heiss; Volker Alt
Journal:  Int Orthop       Date:  2017-12-22       Impact factor: 3.075

4.  Bone Morphogenetic Protein-2 Promotes Human Mesenchymal Stem Cell Survival and Resultant Bone Formation When Entrapped in Photocrosslinked Alginate Hydrogels.

Authors:  Steve S Ho; Nina L Vollmer; Motasem I Refaat; Oju Jeon; Eben Alsberg; Mark A Lee; J Kent Leach
Journal:  Adv Healthc Mater       Date:  2016-09-01       Impact factor: 9.933

Review 5.  [Stimulation of fracture healing by growth factors and cell-based technologies].

Authors:  J Everding; J Stolberg-Stolberg; M J Raschke; R Stange
Journal:  Unfallchirurg       Date:  2019-07       Impact factor: 1.000

6.  [Pseudarthroses of the long bones].

Authors:  J Everding; S Roßlenbroich; M J Raschke
Journal:  Chirurg       Date:  2018-01       Impact factor: 0.955

Review 7.  Non-unions.

Authors:  Giorgio Maria Calori; Emilio Luigi Mazza; Simone Mazzola; Alessandra Colombo; Fabio Giardina; Fabio Romanò; Massimiliano Colombo
Journal:  Clin Cases Miner Bone Metab       Date:  2017-10-25

8.  Three-dimensional Printed Mg-Doped β-TCP Bone Tissue Engineering Scaffolds: Effects of Magnesium Ion Concentration on Osteogenesis and Angiogenesis In Vitro.

Authors:  Yifan Gu; Jing Zhang; Xinzhi Zhang; Guiping Liang; Tao Xu; Wei Niu
Journal:  Tissue Eng Regen Med       Date:  2019-06-17       Impact factor: 4.169

9.  [Bone transplantation or biomaterials? : An analysis of 99,863 surgical procedures in orthopedic and trauma surgery in Germany from 2018].

Authors:  Markus Rupp; Maximilian Kerschbaum; Lisa Klute; Leona Frank; Volker Alt
Journal:  Unfallchirurg       Date:  2021-02       Impact factor: 1.000

10.  Transforaminal Lumbar Interbody Fusion With Viable Allograft: 75 Consecutive Cases at 12-Month Follow-up.

Authors:  William C Tally; H Thomas Temple; T Y Subhawong; Timothy Ganey
Journal:  Int J Spine Surg       Date:  2018-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.