Literature DB >> 25455440

Image guided particle therapy in CNAO room 2: implementation and clinical validation.

G Fattori1, M Riboldi2, A Pella3, M Peroni2, P Cerveri2, M Desplanques4, G Fontana3, B Tagaste3, F Valvo3, R Orecchia5, G Baroni4.   

Abstract

In this contribution we describe the implementation of a novel solution for image guided particle therapy, designed to ensure the maximal accuracy in patient setup. The presented system is installed in the central treatment room at Centro Nazionale di Adroterapia Oncologica (CNAO, Italy), featuring two fixed beam lines (horizontal and vertical) for proton and carbon ion therapy. Treatment geometry verification is based on robotic in-room imaging acquisitions, allowing for 2D/3D registration from double planar kV-images or 3D/3D alignment from cone beam image reconstruction. The calculated six degrees-of-freedom correction vector is transferred to the robotic patient positioning system, thus yielding automated setup error compensation. Sub-millimetre scale residual errors were measured in absolute positioning of rigid phantoms, in agreement with optical- and laser-based assessment. Sub-millimetre and sub-degree positioning accuracy was achieved when simulating setup errors with anthropomorphic head, thorax and pelvis phantoms. The in-house design and development allowed a high level of system customization, capable of replicating the clinical performance of commercially available products, as reported with preliminary clinical results in 10 patients.
Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy measurement; CBCT; IGRT; Image registration; Optical imaging; Robotic imaging

Mesh:

Year:  2014        PMID: 25455440     DOI: 10.1016/j.ejmp.2014.10.075

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  6 in total

Review 1.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

2.  A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

Authors:  Chiaho Hua; Weiguang Yao; Takao Kidani; Kazuo Tomida; Saori Ozawa; Takenori Nishimura; Tatsuya Fujisawa; Ryousuke Shinagawa; Thomas E Merchant
Journal:  Br J Radiol       Date:  2017-10-09       Impact factor: 3.039

3.  Long-time clinical experience in patient setup for several particle therapy clinical indications: management of patient positioning and evaluation of setup reproducibility and stability.

Authors:  Rosalinda Ricotti; Andrea Pella; Barbara Tagaste; Giovanni Elisei; Giulia Fontana; Maria Bonora; Mario Ciocca; Francesca Valvo; Roberto Orecchia; Guido Baroni
Journal:  Br J Radiol       Date:  2019-11-14       Impact factor: 3.629

4.  Image-based shading correction for narrow-FOV truncated pelvic CBCT with deep convolutional neural networks and transfer learning.

Authors:  Matteo Rossi; Gabriele Belotti; Chiara Paganelli; Andrea Pella; Amelia Barcellini; Pietro Cerveri; Guido Baroni
Journal:  Med Phys       Date:  2021-10-26       Impact factor: 4.506

5.  Feasibility Study on Cardiac Arrhythmia Ablation Using High-Energy Heavy Ion Beams.

Authors:  H Immo Lehmann; Christian Graeff; Palma Simoniello; Anna Constantinescu; Mitsuru Takami; Patrick Lugenbiel; Daniel Richter; Anna Eichhorn; Matthias Prall; Robert Kaderka; Fine Fiedler; Stephan Helmbrecht; Claudia Fournier; Nadine Erbeldinger; Ann-Kathrin Rahm; Rasmus Rivinius; Dierk Thomas; Hugo A Katus; Susan B Johnson; Kay D Parker; Jürgen Debus; Samuel J Asirvatham; Christoph Bert; Marco Durante; Douglas L Packer
Journal:  Sci Rep       Date:  2016-12-20       Impact factor: 4.379

6.  Time-resolved MRI for off-line treatment robustness evaluation in carbon-ion radiotherapy of pancreatic cancer.

Authors:  Giorgia Meschini; Alessandro Vai; Amelia Barcellini; Giulia Fontana; Silvia Molinelli; Edoardo Mastella; Andrea Pella; Viviana Vitolo; Sara Imparato; Ester Orlandi; Mario Ciocca; Guido Baroni; Chiara Paganelli
Journal:  Med Phys       Date:  2022-02-17       Impact factor: 4.506

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.