Literature DB >> 25455194

Relationship between second- and third-order acoustic nonlinear parameters in relative measurement.

Gang Ren1, Jongboem Kim1, Kyung-Young Jhang2.   

Abstract

The higher-order acoustic nonlinear parameters are considered effective damage indices in the field of nondestructive evaluation (NDE). They are defined by using the displacement amplitudes of the fundamental frequency and the harmonics, which are called the absolute nonlinear parameters. Generally, however, it is difficult to measure the very small displacement amplitudes of high-frequency harmonics. Therefore, the simplified parameters using the detected wave signal amplitudes, which are known as the relative nonlinear parameters, have been widely used, although their applications are limited to the relative comparison of before and after damage of a single material under consistent experimental circumstances. In this paper, in order to make clear the concept of relative parameter, we presented first that the relative ratio of the simplified parameters is identical to that of the absolute parameters when the detected signal amplitudes are linearly proportional to the actual displacement amplitudes with respect to the fundamental frequency and the harmonics. In addition, the new relationship between the relative ratio of simplified second-order parameter and the relative ratio of simplified third-order parameter was derived from the relationship between the absolute second- and third-order parameters. This new relationship was successfully verified based on experimental results obtained from Al 6061-T6 processed for different heat treatment times, where it was confirmed in advance that the PZT detection signal amplitudes at the fundamental frequency and its second- and third-order harmonics were linearly proportional to the displacement amplitudes.
Copyright © 2014 Elsevier B.V. All rights reserved.

Keywords:  Acoustic nonlinearity; Material degradation; Relative measurement; Simplified nonlinear parameter; Thermal aging

Year:  2014        PMID: 25455194     DOI: 10.1016/j.ultras.2014.10.009

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  1 in total

1.  Analysis of Platen Superheater Tube Degradation in Thermal Power Plants via Destructive/Non-Destructive Characteristic Evaluation.

Authors:  Se-Beom Oh; Jongbeom Kim; Soon-Woo Han; Kyung-Mo Kim; Dong-Seok Yun; Dong-Wook Kim
Journal:  Materials (Basel)       Date:  2022-01-13       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.