Design optimization of a deflectable guidewire.

H C M Clogenson1, A Simonetto2, J J van den Dobbelsteen3.   

Abstract

Over the years, the design of the tip of available catheters and guidewires has evolved into various shapes whose geometry is mostly based on common sense and experimentation. However, while the tip shape of conventional instruments can be easily modified and tested, the length of the tip of a deflectable guidewire cannot. Hence, other approaches are necessary in order to determine the proper dimensions of original instruments. In this paper, we formulate the length of the different parts of the deflectable tip of a guidewire as an optimization problem with the objective to obtain a design that is suitable for cannulating several target bifurcations of the peripheral vasculature. A direct relationship between the design of the deflectable tip and the geometry of the target bifurcations was found and the optimal dimension of the tip of the instrument was computed. Following the length specifications defined by the optimization, a new prototype was assembled, and evaluated. The deflectable guidewire could successfully cannulate most of the pre-selected branches except those bifurcations with an angle α>70°. The latter limitation could be ascribed to the mechanical properties of the instrument.
Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Keywords:  Bifurcations; Deflectable tip; Design; Endovascular; Guidewire; Navigation; Optimization; Peripheral vasculature

Mesh:

Year:  2014        PMID: 25455166     DOI: 10.1016/j.medengphy.2014.10.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Towards FBG-Based Shape Sensing for Micro-scale and Meso-Scale Continuum Robots with Large Deflection.

Authors:  Yash Chitalia; Nancy Joanna Deaton; Seokhwan Jeong; Nahian Rahman; Jaydev P Desai
Journal:  IEEE Robot Autom Lett       Date:  2020-01-28

2.  Electrothermally Driven Hydrogel-on-Flex-Circuit Actuator for Smart Steerable Catheters.

Authors:  Madeshwaran Selvaraj; Kenichi Takahata
Journal:  Micromachines (Basel)       Date:  2020-01-08       Impact factor: 2.891

3.  The Columbus steerable guidewire in neurointerventions: early clinical experience and applications.

Authors:  Alexander von Hessling; Tomás Reyes Del Castillo; Grzegorz Karwacki; Justus E Roos
Journal:  J Neurointerv Surg       Date:  2021-05-04       Impact factor: 5.836

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.