Literature DB >> 25453582

A comparison of bleeding patterns and cycle control using two transdermal contraceptive systems: a multicenter, open-label, randomized study.

D Gruber1, A Skřivánek2, M Serrani3, V Lanius3, M Merz4.   

Abstract

OBJECTIVE(S): To investigate the bleeding pattern and cycle control parameters of a contraceptive patch containing 0.55 mg ethinyl estradiol (EE) and 2.1 mg gestodene (GSD) compared with a patch containing 0.6 mg EE and 6 mg norelgestromin (NGMN). STUDY
DESIGN: In this phase III, open-label, randomized, parallel-group trial, healthy women aged 18-35 years (smokers aged 18-30 years) received either the EE/GSD patch (n=200) or the EE/NGMN patch (n=198). Treatment consisted of one patch per week for 3 weeks followed by a 7-day, patch-free interval for seven cycles. Bleeding control was assessed in two 90-day reference periods.
RESULTS: In reference period 1, mean number of bleeding/spotting days was comparable across treatment groups (p>0.05). However, in reference period 2, there were fewer bleeding/spotting days in the EE/GSD patch group (15.7 versus 18.4; p<0.0001). Mean number of bleeding/spotting episodes was comparable across groups for both reference periods, but bleeding/spotting episodes were shorter for the EE/GSD patch than the EE/NGMN patch during reference period 1 (5.13 days versus 5.53 days, respectively; p<0.05) and reference period 2 (5.07 versus 5.66; p=0.0001). Both treatment groups showed a similar frequency of withdrawal bleeding episodes; however, across all seven cycles, the length of these episodes was consistently shorter with the EE/GSD patch (p<0.01). There were no notable treatment differences in intracyclic bleeding. CONCLUSION(S): Bleeding pattern and cycle control achieved with the EE/GSD patch was similar to that of the EE/NGMN patch. IMPLICATIONS STATEMENT: The paper presents data on the bleeding pattern and cycle control parameters of an investigational transdermal contraceptive patch containing EE and GSD compared with an approved contraceptive patch containing EE and NGMN. This descriptive study found that bleeding patterns associated with the EE/GSD patch were similar to those of an EE/NGMN patch providing higher EE exposure.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bleeding pattern; Cycle control; Ethinyl estradiol; Gestodene; Tolerability; Transdermal contraceptive patch

Mesh:

Substances:

Year:  2014        PMID: 25453582     DOI: 10.1016/j.contraception.2014.10.003

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  2 in total

Review 1.  Transdermal delivery of combined hormonal contraception: a review of the current literature.

Authors:  Rosanna M Galzote; Sally Rafie; Rachel Teal; Sheila K Mody
Journal:  Int J Womens Health       Date:  2017-05-15

2.  An open-label, two-period comparative study on pharmacokinetics and safety of a combined ethinylestradiol/gestodene transdermal contraceptive patch.

Authors:  Chao Zhang; Haiyan Li; Xin Xiong; Suodi Zhai; Yudong Wei; Shuang Zhang; Yuanyuan Zhang; Lin Xu; Li Liu
Journal:  Drug Des Devel Ther       Date:  2017-03-10       Impact factor: 4.162

  2 in total