Literature DB >> 25453565

Effect of surface treatments on the shear bond strength of luting cements to Y-TZP ceramic.

Plínio Sciasci1, Filipe Oliveira Abi-Rached2, Gelson Luis Adabo3, Paolo Baldissara4, Renata Garcia Fonseca5.   

Abstract

STATEMENT OF PROBLEM: Because zirconia is a glass-free material, alternative surface treatments such as airborne-particle abrasion or silica coating should be used for long-term bonding. However, these surface treatments in combination with different bonding agents and luting cements have not yet been studied.
PURPOSE: The purpose of the study was to evaluate the effect of surface treatments on the shear bond strength (SBS) of luting cements to Y-TZP ceramic.
MATERIAL AND METHODS: Zirconia disks (N=240) were airborne-particle abraded with the following particles (n=48): 50 μm Al2O3; 120 μm Al2O3; 30 μm silica-coated Al2O3 (Rocatec Soft); 120 μm Al2O3+110 μm silica-coated Al2O3 (Rocatec Plus); and Rocatec Plus. After silanization of the zirconia surface, composite resin disks were bonded with (n=12) RelyX Luting 2; RelyX ARC; RelyX U100; and Panavia F. The bonded specimens were thermocycled (10 000 cycles) and tested for SBS. Failure mode was determined with a stereomicroscope (×20). The morphology and elemental composition of airborne-particle abraded surfaces were evaluated with scanning electron microscopy (×500) and energy-dispersive x-ray spectroscopy (×50).
RESULTS: Surface treatments, cements, and their interaction were significant (P<.001). For RelyX ARC, Rocatec Soft and Rocatec Plus provided the highest SBS. In general, surface treatments did not influence the SBS of RelyX U100 and Panavia F. Regardless of the cement, no significant difference was found between 50 μm and 120 μm Al2O3 particles, between Rocatec Soft and Rocatec Plus, or between Rocatec Plus and 120 μm Al2O3 particles+Rocatec Plus. All groups showed adhesive failures. Different particle sizes provided differences in morphological patterns. The elemental composition comprised Al and Al/Si for alumina and silica-abraded zirconia.
CONCLUSIONS: Particle size did not influence the SBS of the groups abraded exclusively with alumina or silica-coated particles. RelyX ARC was more surface-treatment dependent than RelyX U100 or Panavia F.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25453565     DOI: 10.1016/j.prosdent.2014.09.012

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment.

Authors:  Thomas Strasser; Verena Preis; Michael Behr; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-02-05       Impact factor: 3.573

2.  Shear Bond Strength of Al₂O₃ Sandblasted Y-TZP Ceramic to the Orthodontic Metal Bracket.

Authors:  Seon Mi Byeon; Min Ho Lee; Tae Sung Bae
Journal:  Materials (Basel)       Date:  2017-02-09       Impact factor: 3.623

Review 3.  Zirconia as a Dental Biomaterial.

Authors:  Alvaro Della Bona; Oscar E Pecho; Rodrigo Alessandretti
Journal:  Materials (Basel)       Date:  2015-08-04       Impact factor: 3.623

4.  Bond strength of zirconia- or polymer-based copings cemented on implant-supported titanium bases - an in vitro study.

Authors:  Eliann Oddbratt; Lisa Hua; Bruno R Chrcanovic; Evaggelia Papia
Journal:  Biomater Investig Dent       Date:  2021-09-13

Review 5.  Adhesion to Zirconia: A Systematic Review of Current Conditioning Methods and Bonding Materials.

Authors:  Daniele Scaminaci Russo; Francesca Cinelli; Chiara Sarti; Luca Giachetti
Journal:  Dent J (Basel)       Date:  2019-08-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.