Perfusion assessment in laparoscopic left-sided/anterior resection (PILLAR II): a multi-institutional study.

Mehraneh D Jafari1, Steven D Wexner2, Joseph E Martz3, Elisabeth C McLemore4, David A Margolin5, Danny A Sherwinter6, Sang W Lee7, Anthony J Senagore8, Michael J Phelan1, Michael J Stamos9.   

Abstract

BACKGROUND: Our primary objective was to demonstrate the utility and feasibility of the intraoperative assessment of colon and rectal perfusion using fluorescence angiography (FA) during left-sided colectomy and anterior resection. Anastomotic leak (AL) after colorectal resection increases morbidity, mortality, and, in cancer cases, recurrence rates. Inadequate perfusion may contribute to AL. The PINPOINT Endoscopic Fluorescence Imaging System allows for intraoperative assessment of anastomotic perfusion. STUDY
DESIGN: This is a prospective, multicenter, open-label, clinical trial that assessed the feasibility and utility of FA for intraoperative perfusion assessment during left-sided colectomy and anterior resection at 11 centers in the United States.
RESULTS: A total of 147 patients were enrolled, of whom 139 were eligible for analysis. Diverticulitis (44%), rectal cancer (25%), and colon cancer (21%) were the most prevalent indications for surgery. The mean level of anastomosis was 10 ± 4 cm from the anal verge. Splenic-flexure mobilization was performed in 81% and high ligation of the inferior mesenteric artery in 61.9% of patients. There was a 99% success rate for FA, and FA changed surgical plans in 11 (8%) patients, with the majority of changes occurring at the time of transection of the proximal margin (7%). Overall morbidity rates were 17%. The anastomotic leak rate was 1.4% (n = 2). There were no anastomotic leaks in the 11 patients who had a change in surgical plan based on intraoperative perfusion assessment with FA.
CONCLUSIONS: PINPOINT is a safe and feasible tool for intraoperative assessment of tissue perfusion during colorectal resection. There were no anastomotic leaks in patients in whom the anastomosis was revised based on inadequate perfusion with FA.
Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25451666     DOI: 10.1016/j.jamcollsurg.2014.09.015

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  141 in total

Review 1.  The quest for precision in transanal total mesorectal excision.

Authors:  A G Franchini Melani; M Diana; J Marescaux
Journal:  Tech Coloproctol       Date:  2015-11-26       Impact factor: 3.781

2.  Evaluation of intestinal perfusion by ICG fluorescence imaging in laparoscopic colorectal surgery with DST anastomosis.

Authors:  Kenji Kawada; Suguru Hasegawa; Toshiaki Wada; Ryo Takahashi; Shigeo Hisamori; Koya Hida; Yoshiharu Sakai
Journal:  Surg Endosc       Date:  2016-06-28       Impact factor: 4.584

3.  A Novel Application of Indocyanine Green Immunofluorescence in Emergent Colorectal Surgery.

Authors:  Deborah S Keller; Richard Boulton; Manuel Rodriguez-Justo; Richard Cohen; Manish Chand
Journal:  J Fluoresc       Date:  2018-04-26       Impact factor: 2.217

Review 4.  Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage.

Authors:  Sami A Chadi; Abe Fingerhut; Mariana Berho; Steven R DeMeester; James W Fleshman; Neil H Hyman; David A Margolin; Joseph E Martz; Elisabeth C McLemore; Daniela Molena; Martin I Newman; Janice F Rafferty; Bashar Safar; Anthony J Senagore; Oded Zmora; Steven D Wexner
Journal:  J Gastrointest Surg       Date:  2016-09-16       Impact factor: 3.452

5.  Recent Publications by Ochsner Authors.

Authors: 
Journal:  Ochsner J       Date:  2015

Review 6.  Techniques in total mesorectal excision surgery.

Authors:  Warren E Lichliter
Journal:  Clin Colon Rectal Surg       Date:  2015-03

7.  Safety and effectiveness of high ligation of the inferior mesenteric artery for cancer of the descending colon under indocyanine green fluorescence imaging: a pilot study.

Authors:  Taro Munechika; Ryuji Kajitani; Yoshiko Matsumoto; Hideki Nagano; Akira Komono; Naoya Aisu; Mitsuaki Morimoto; Gumpei Yoshimatsu; Yoichiro Yoshida; Suguru Hasegawa
Journal:  Surg Endosc       Date:  2020-04-15       Impact factor: 4.584

8.  Feasibility of fluorescence lymph node imaging in colon cancer: FLICC.

Authors:  M Chand; D S Keller; H M Joshi; L Devoto; M Rodriguez-Justo; R Cohen
Journal:  Tech Coloproctol       Date:  2018-03-17       Impact factor: 3.781

9.  Evaluation of lymph flow patterns in splenic flexural colon cancers using laparoscopic real-time indocyanine green fluorescence imaging.

Authors:  Jun Watanabe; Mitsuyoshi Ota; Yusuke Suwa; Atsushi Ishibe; Hidenobu Masui; Kaoru Nagahori
Journal:  Int J Colorectal Dis       Date:  2016-10-01       Impact factor: 2.571

10.  The impact of near-infrared angiography and proctoscopy after rectosigmoid resection and anastomosis performed during surgeries for gynecologic malignancies.

Authors:  Lea A Moukarzel; Maureen E Byrne; Stephanie Leiva; Michelle Wu; Qin C Zhou; Alexia Iasonos; Nadeem R Abu-Rustum; Yukio Sonoda; Ginger Gardner; Mario M Leitao; Vance A Broach; Dennis S Chi; Kara Long Roche; Oliver Zivanovic
Journal:  Gynecol Oncol       Date:  2020-05-24       Impact factor: 5.482

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.