Literature DB >> 25450795

Minimizing inhibition of PCR-STR typing using digital agarose droplet microfluidics.

Tao Geng1, Richard A Mathies2.   

Abstract

The presence of PCR inhibitors in forensic and other biological samples reduces the amplification efficiency, sometimes resulting in complete PCR failure. Here we demonstrate a high-performance digital agarose droplet microfluidics technique for single-cell and single-molecule forensic short tandem repeat (STR) typing of samples contaminated with high concentrations of PCR inhibitors. In our multifaceted strategy, the mitigation of inhibitory effects is achieved by the efficient removal of inhibitors from the porous agarose microgel droplets carrying the DNA template through washing and by the significant dilution of targets and remaining inhibitors to the stochastic limit within the ultralow nL volume droplet reactors. Compared to conventional tube-based bulk PCR, our technique shows enhanced (20 ×, 10 ×, and 16 ×) tolerance of urea, tannic acid, and humic acid, respectively, in STR typing of GM09948 human lymphoid cells. STR profiling of single cells is not affected by small soluble molecules like urea and tannic acid because of their effective elimination from the agarose droplets; however, higher molecular weight humic acid still partially inhibits single-cell PCR when the concentration is higher than 200 ng/μL. Nevertheless, the full STR profile of 9948 male genomic DNA contaminated with 500 ng/μL humic acid was generated by pooling and amplifying beads carrying single-molecule 9948 DNA PCR products in a single secondary reaction. This superior performance suggests that our digital agarose droplet microfluidics technology is a promising approach for analyzing low-abundance DNA targets in the presence of inhibitors.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Digital droplet microfluidics; Forensic DNA analysis; PCR inhibition; Short tandem repeat (STR) typing; Single-cell PCR; Single-molecule PCR

Mesh:

Substances:

Year:  2014        PMID: 25450795     DOI: 10.1016/j.fsigen.2014.10.007

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  3 in total

1.  Validation of the AGCU Expressmarker 16 + 22Y Kit: a new multiplex for forensic application.

Authors:  Mingkun Xie; Feng Song; Jienan Li; Bowen Xie; Shuangshuang Wang; Weizhi Wang; Hong Ma; Haibo Luo
Journal:  Int J Legal Med       Date:  2019-11-12       Impact factor: 2.686

Review 2.  Microfluidic Devices for Forensic DNA Analysis: A Review.

Authors:  Brigitte Bruijns; Arian van Asten; Roald Tiggelaar; Han Gardeniers
Journal:  Biosensors (Basel)       Date:  2016-08-05

3.  Evaluation of a six-dye multiplex composed of 27 markers for forensic analysis and databasing.

Authors:  Shuangshuang Wang; Feng Song; Mingkun Xie; Ke Zhang; Bowen Xie; Zhanglong Huang; Haibo Luo
Journal:  Mol Genet Genomic Med       Date:  2020-07-16       Impact factor: 2.183

  3 in total