Influence of calibration protocols for a pressure-sensing walkway on kinetic and temporospatial parameters.

F S Agostinho, S C Rahal1, B Geraldo, P L T Justolin, C R Teixeira, F L M L Lins, F O B Monteiro.   

Abstract

OBJECTIVES: To evaluate the influence on the kinetic and temporospatial parameters of calibration protocols with point and step techniques for a pressure-sensing walkway.
METHODS: Nine Labrador dogs were used. Two protocols of point calibration technique (C1 and C2) and eight protocols of step calibration technique (C3 to C10) were performed. In C1, weight was added to a stool to match the body mass of each dog. In C2, weight was added to the stool to match a 46.1 kg person. The other eight calibration protocols represented combinations of the following factors: 46.1 kg and 96.1 kg persons, barefoot or wearing sneakers, and stepping onto the platform with one or two feet.
RESULTS: The calibration protocols did not affect the temporospatial variables or percentages of body weight (%BW) distribution. Significant differences were found in both PVI (peak vertical force) and VI (vertical impulse) between barefoot versus wearing sneakers, 46.1 kg versus 96.1 kg person, and stepping onto the platform with one foot versus two feet. When comparing C1 with other protocols, significant differences were observed in PVF and VI for both forelimbs and hindlimbs. When comparing C2 with other protocols, significant differences were observed in PVF and VI for both forelimbs and hindlimbs in all protocols. CLINICAL SIGNIFICANCE: The PVF and VI were influenced by the calibration protocol used, but the %BW distribution and temporospatial parameters were not. Using the same calibration protocol for all dogs within the same group eliminated the variability of the kinetic data caused by the calibration.

Entities:  

Keywords:  Pressure platform; Tekscan; calibration

Mesh:

Year:  2014        PMID: 25450155     DOI: 10.3415/VCOT-14-05-0081

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  3 in total

1.  Use of a pressure-sensing walkway system for biometric assessment of gait characteristics in goats.

Authors:  Rebecca E Rifkin; Remigiusz M Grzeskowiak; Pierre-Yves Mulon; H Steve Adair; Alexandru S Biris; Madhu Dhar; David E Anderson
Journal:  PLoS One       Date:  2019-10-16       Impact factor: 3.240

2.  Kinetic gait analysis in healthy dogs and dogs with osteoarthritis: An evaluation of precision and overlap performance of a pressure-sensitive walkway and the use of symmetry indices.

Authors:  Michelle Brønniche Møller Nielsen; Tenna Pedersen; Amalie Mouritzen; Anne Desiré Vitger; Lise Nikolic Nielsen; Helle Harding Poulsen; James Edward Miles
Journal:  PLoS One       Date:  2020-12-15       Impact factor: 3.240

3.  Pressure Mat Analysis of Walk and Trot Gait Characteristics in 66 Normal Small, Medium, Large, and Giant Breed Dogs.

Authors:  Maria A Fahie; Jonathan C Cortez; Marc Ledesma; Yuhua Su
Journal:  Front Vet Sci       Date:  2018-10-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.