Literature DB >> 25448622

Label electrochemical immunosensor for prostate-specific antigen based on graphene and silver hybridized mesoporous silica.

Yueyun Li1, Jian Han2, Runhai Chen2, Xiang Ren3, Qin Wei3.   

Abstract

Prostate-specific antigen (PSA), as the specificity of prostate cancer markers, has been widely used in prostate cancer diagnosis and screening. In this study, we fabricated an electrochemical immunosensor for PSA detection using the amino-functionalized graphene sheet-ferrocenecarboxaldehyde composite materials (NH2-GS@FCA) and silver hybridized mesoporous silica nanoparticles (Ag@NH2-MCM48). Under optimal conditions, the fabricated immunosensor showed a wide linear range with PSA concentration (0.01-10.0ng·ml(-1)). Low detection limit (2pg·ml(-1)) proved the high sensitivity. In addition, the immunosensor possessed good stability and reproducibility. Moreover, the application to PSA analysis in serum samples yielded satisfactory results.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Immunosensor; Prostate-specific antigen; Silver hybridized mesoporous silica nanoparticles

Mesh:

Substances:

Year:  2014        PMID: 25448622     DOI: 10.1016/j.ab.2014.09.022

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  Recent advances in graphene-based nanomaterials: properties, toxicity and applications in chemistry, biology and medicine.

Authors:  Jun Yao; Heng Wang; Min Chen; Mei Yang
Journal:  Mikrochim Acta       Date:  2019-06-01       Impact factor: 5.833

Review 2.  Critical overview on the application of sensors and biosensors for clinical analysis.

Authors:  Celine I L Justino; Armando C Duarte; Teresa A P Rocha-Santos
Journal:  Trends Analyt Chem       Date:  2016-04-08       Impact factor: 12.296

3.  Use of data processing for rapid detection of the prostate-specific antigen biomarker using immunomagnetic sandwich-type sensors.

Authors:  Camila A Proença; Tayane A Freitas; Thaísa A Baldo; Elsa M Materón; Flávio M Shimizu; Gabriella R Ferreira; Frederico L F Soares; Ronaldo C Faria; Osvaldo N Oliveira
Journal:  Beilstein J Nanotechnol       Date:  2019-11-06       Impact factor: 3.649

Review 4.  Graphene: The Missing Piece for Cancer Diagnosis?

Authors:  Sandra M A Cruz; André F Girão; Gil Gonçalves; Paula A A P Marques
Journal:  Sensors (Basel)       Date:  2016-01-21       Impact factor: 3.576

5.  Aberrant sialylation of a prostate-specific antigen: Electrochemical label-free glycoprofiling in prostate cancer serum samples.

Authors:  Dominika Pihikova; Peter Kasak; Petra Kubanikova; Roman Sokol; Jan Tkac
Journal:  Anal Chim Acta       Date:  2016-07-01       Impact factor: 6.558

  5 in total