Literature DB >> 25446736

Digital evaluation of the accuracy of impression techniques and materials in angulated implants.

Sevcan Kurtulmus-Yilmaz1, Oguz Ozan2, Tuncer Burak Ozcelik3, Ayberk Yagiz4.   

Abstract

OBJECTIVES: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants.
METHODS: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10° or 20° angulated) were fabricated. Two different impression techniques [splinted direct (D), indirect (I)] and 3 different monophase impression materials [polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n=10). Master model and casts were scanned by a modified laser scanner and data were transferred to VRMesh software. Master model and duplicate cast scans were digitally aligned observing the superposition of anatomic markers. Angular and coronal deviations between master and duplicated copings were calculated and data were statistically analyzed.
RESULTS: Mean angular and coronal deviations were in a range of 0.205-0.359° and 22.56-33.33μm, respectively. Statistical analysis revealed that the angulation of implant affected both coronal and angular deviations of the impression copings (P<0.05). According to statistical analyses, for parallel implants, the accuracy of impression materials and techniques were ranging as VPS-D=PE-D>VPS-I=PE-I>VPES-D>VPES-I from most accurate to the least. For 10° and 20° angulated implants the most accurate material and technique was VPS-D whereas the least accurate combination was VPES-I (P<0.05).
CONCLUSION: Angulation, impression technique and material were found to be effective on the accuracy of implant impressions. CLINICAL SIGNIFICANCE: Clinicians may prefer VPS impression material and splinted direct technique for impressions of both parallel and up to 20° angulated implants.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Implant angulation; Indirect technique; Polyether; Splinted direct technique; Vinyl polyether silicone; Vinyl polysiloxane

Mesh:

Substances:

Year:  2014        PMID: 25446736     DOI: 10.1016/j.jdent.2014.10.008

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  9 in total

1.  Effect of Core Materials on the Dimensional Accuracy of Casts Made of Two Different Silicone Impression Materials: An Experimental Study.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Mohammad-Hassan Kalantari
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-05

Review 2.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

3.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

4.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

5.  Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Authors:  Daniela Djurovic Koprivica; Tatjana Puskar; Igor Budak; Mario Sokac; Milica Jeremic Knezevic; Aleksandra Maletin; Bojana Milekic; Djordje Vukelic
Journal:  Polymers (Basel)       Date:  2022-07-11       Impact factor: 4.967

6.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

7.  Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions.

Authors:  Hakimeh Siadat; Zeinab Saeidi; Marzieh Alikhasi; Somayeh Zeighami
Journal:  J Clin Exp Dent       Date:  2018-11-01

8.  The Accuracy of Open-Tray vs. Snap on Impression Techniques in A 6-Implant Model: An In Vitro 3D Study.

Authors:  Adi Arieli; Maram Adawi; Mahmoud Masri; Evgeny Weinberg; Ilan Beitlitum; Raphael Pilo; Shifra Levartovsky
Journal:  Materials (Basel)       Date:  2022-03-12       Impact factor: 3.623

9.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
  9 in total