Min Ji Hong1, Jung Hwan Baek2, Young Jun Choi1, Jeong Hyun Lee1, Hyun Kyung Lim3, Young Kee Shong4, Suck Joon Hong5. 1. Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-gu, Seoul, 138-736, Republic of Korea. 2. Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-gu, Seoul, 138-736, Republic of Korea. Electronic address: radbaek@naver.com. 3. Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-gu, Seoul, 138-736, Republic of Korea; Department of Radiology, Soonchunhyang University Hospital, Seoul, Republic of Korea. 4. Department of Endocrinology and Metabolism, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-gu, Seoul, 138-736, Republic of Korea. 5. Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-Gil, Songpa-gu, Seoul, 138-736, Republic of Korea.
Abstract
PURPOSE: To evaluate the efficacy and safety of radiofrequency (RF) ablation for treatment of bilateral thyroid nodules as well as preservation of thyroid function. MATERIALS AND METHODS: Between January 2007 and October 2012, 18 patients (16 women and 2 men; mean age, 49.9 y; median age, 44 y; age range, 27-81 y) with bilateral thyroid nodules treated by RF ablation were included in this study. The inclusion criteria included bilateral thyroid nodules, pressure symptoms or cosmetic problems, cytologic confirmation of benignancy without atypical cells, and patient refusal of surgery. We used an RF generator (Cool-tip RF system [Covidien, Boulder, Colorado] or SSP-2000, Taewoong Medical Co, Ltd [Gyeonggi-do, Republic of Korea]) and an 18-gauge internally cooled electrode with 1-cm active tips (Cool-tip [Covidien] or Well-Point RF electrode [Taewoong Medical Co, Ltd]). RF ablation was conducted using the moving shot technique and a trans-isthmic approach. RF ablation was performed in separate sessions for nodules in each lobe. Follow-up ultrasound examinations were performed at 1-6 months, 6-12 months, and during the last month of follow-up. The diameter and volume of the nodule and clinical problems including cosmetic and symptom scores were evaluated before and after the procedure. RESULTS: The mean initial nodule size was 4.1 cm ± 1.9, although there was a significant decrease by the time of the last follow-up examination (range, 1-48 mo; mean, 18.1 mo ± 12.8; P < .001, 2.5 cm ± 1.4). The initial nodule volume was 24.4 mL ± 32.2 and was decreased at the last follow-up (6.3 mL ± 19.0, P < .001), with a mean volume reduction of 75.9% ± 19.0. The symptom (P < .001) and cosmetic (P < .001) scores were decreased. Serum hormone levels did not differ significantly before treatment and at the last follow-up (P > .05). CONCLUSIONS: RF ablation improves cosmetic problems and symptoms and preserves thyroid function in patients with bilateral thyroid nodules.
PURPOSE: To evaluate the efficacy and safety of radiofrequency (RF) ablation for treatment of bilateral thyroid nodules as well as preservation of thyroid function. MATERIALS AND METHODS: Between January 2007 and October 2012, 18 patients (16 women and 2 men; mean age, 49.9 y; median age, 44 y; age range, 27-81 y) with bilateral thyroid nodules treated by RF ablation were included in this study. The inclusion criteria included bilateral thyroid nodules, pressure symptoms or cosmetic problems, cytologic confirmation of benignancy without atypical cells, and patient refusal of surgery. We used an RF generator (Cool-tip RF system [Covidien, Boulder, Colorado] or SSP-2000, Taewoong Medical Co, Ltd [Gyeonggi-do, Republic of Korea]) and an 18-gauge internally cooled electrode with 1-cm active tips (Cool-tip [Covidien] or Well-Point RF electrode [Taewoong Medical Co, Ltd]). RF ablation was conducted using the moving shot technique and a trans-isthmic approach. RF ablation was performed in separate sessions for nodules in each lobe. Follow-up ultrasound examinations were performed at 1-6 months, 6-12 months, and during the last month of follow-up. The diameter and volume of the nodule and clinical problems including cosmetic and symptom scores were evaluated before and after the procedure. RESULTS: The mean initial nodule size was 4.1 cm ± 1.9, although there was a significant decrease by the time of the last follow-up examination (range, 1-48 mo; mean, 18.1 mo ± 12.8; P < .001, 2.5 cm ± 1.4). The initial nodule volume was 24.4 mL ± 32.2 and was decreased at the last follow-up (6.3 mL ± 19.0, P < .001), with a mean volume reduction of 75.9% ± 19.0. The symptom (P < .001) and cosmetic (P < .001) scores were decreased. Serum hormone levels did not differ significantly before treatment and at the last follow-up (P > .05). CONCLUSIONS:RF ablation improves cosmetic problems and symptoms and preserves thyroid function in patients with bilateral thyroid nodules.
Authors: Anna Pisani Mainini; Cristian Monaco; Lorenzo Carlo Pescatori; Chiara De Angelis; Francesco Sardanelli; Luca Maria Sconfienza; Giovanni Mauri Journal: J Ultrasound Date: 2016-10-21
Authors: Pierre Yves Marcy; Jonathan Barbut; Anne Sophie Bertrand; Alexis Lacout; Jean Baptiste Morvan Journal: World J Surg Date: 2020-04 Impact factor: 3.352
Authors: Yücel Korkusuz; Alexander Mader; Daniel Gröner; Shadi Ahmad; Oscar Maximilian Mader; Frank Grünwald; Christian Happel Journal: World J Surg Date: 2017-10 Impact factor: 3.352
Authors: Jung Hwan Baek; Eun Ju Ha; Young Jun Choi; Jin Yong Sung; Jae Kyun Kim; Young Kee Shong Journal: Korean J Radiol Date: 2015-10-26 Impact factor: 3.500