Literature DB >> 25446159

Reduced incidence of esophageal lesions by luminal esophageal temperature-guided second-generation cryoballoon ablation.

Alexander Fürnkranz1, Stefano Bordignon2, Michael Böhmig3, Athanasios Konstantinou2, Daniela Dugo2, Laura Perrotta2, Tom Klopffleisch3, Bernd Nowak2, Axel U Dignaß3, Boris Schmidt2, Julian K R Chun2.   

Abstract

BACKGROUND: An increased incidence of esophageal lesions (EL) after pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB2) has been described. We hypothesized that luminal esophageal temperature (LET)-guided PVI reduces the incidence of EL.
OBJECTIVE: The aim of this study was to investigate the incidence of EL after LET-guided PVI using the CB2.
METHODS: Ninety-four consecutive patients underwent CB2-PVI for paroxysmal or persistent atrial fibrillation. Target freezing time was 2 × 240 seconds. LET was continuously measured by a probe with 3 thermocouples. Early freezing interruption was performed when LET reached a prespecified cutoff temperature. A group of 32 patients who underwent CB2-PVI with observational LET measurement served as the control group. Postprocedural esophagoscopy was performed in all patients.
RESULTS: Compared with observational LET measurement, a strategy of LET-guided CB-PVI significantly reduced the incidence of EL from 18.8% to 3.2% (P = .008). A progressive decline in the incidence of EL was observed with an increasing LET cutoff: 7.1% (2/28 patients, 12°C cutoff) and 1.5% (1/66 patients, 15°C cutoff, P = .005 vs control). Despite early freezing interruption at a single pulmonary vein in 27% (25/94) of patients, complete PVI was achieved in all patients using the 28 mm balloon. Repeat esophagoscopy confirmed healing of EL after 1 week. After a mean of 268 ± 119 days, 87% (76/87) of patients were free of recurrent atrial fibrillation or atrial tachycardia following a 90-days blanking period.
CONCLUSION: LET-guided CB2-PVI significantly reduced the incidence of thermal EL. Interrupting cryoablation at 15°C LET was associated with the lowest incidence of esophageal injury.
Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Complication; Cryoballoon; Esophageal injury

Mesh:

Year:  2014        PMID: 25446159     DOI: 10.1016/j.hrthm.2014.10.033

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  21 in total

Review 1.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

2.  Practical Techniques in Cryoballoon Ablation: How to Isolate Inferior Pulmonary Veins.

Authors:  Shaojie Chen; Boris Schmidt; Stefano Bordignon; Fabrizio Bologna; Takahiko Nagase; Laura Perrotta; K R Julian Chun
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-03

3.  Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures.

Authors:  Giacomo Mugnai; Darragh Moran; Erwin Ströker; Diego Ruggiero; Hugo Enrique Coutino-Moreno; Ken Takarada; Valentina De Regibus; Rajin Choudhury; Saverio Iacopino; Pasquale Filannino; Vincent Umbrain; Stefan Beckers; Pedro Brugada; Carlo de Asmundis; Gian-Battista Chierchia
Journal:  J Interv Card Electrophysiol       Date:  2016-08-15       Impact factor: 1.900

4.  Short tip-big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon.

Authors:  Christian-H Heeger; Erik Wissner; Shibu Mathew; Kentaro Hayashi; Christian Sohns; Bruno Reißmann; Christine Lemes; Tilmann Maurer; Thomas Fink; Ardan M Saguner; Francesco Santoro; Johannes Riedl; Feifan Ouyang; Karl-Heinz Kuck; Andreas Metzner
Journal:  Clin Res Cardiol       Date:  2015-11-25       Impact factor: 5.460

Review 5.  Outcomes Of Cryoballoon Ablation Of Atrial Fibrillation: A Comprehensive Review.

Authors:  Arash Aryana; Mark R Bowers; Padraig Gearoid O'Neill
Journal:  J Atr Fibrillation       Date:  2015-08-31

6.  How to Prevent, Detect and Manage Complications Caused by Cryoballoon Ablation of Atrial Fibrillation.

Authors:  Nitin Kulkarni; Wilber Su; Richard Wu
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-03

7.  Pulmonary vein isolation using second-generation single-shot devices: not all the same?

Authors:  Philipp Seidl; Frank Steinborn; Lisa Costello-Boerrigter; Ralf Surber; Paul C Schulze; Christine Böttcher; Andreas Sommermeier; Violeta Mattea; Roland Simeoni; Frank Michael Malur; Harald Lapp; Anja Schade
Journal:  J Interv Card Electrophysiol       Date:  2020-05-15       Impact factor: 1.900

8.  Novel three-dimensional imaging approach for cryoballoon navigation and confirmation of pulmonary vein occlusion.

Authors:  Christopher A B Kowalewski; Miguel Rodrigo; Chad Brodt; Francois Haddad; Paul J Wang; Sanjiv M Narayan
Journal:  Pacing Clin Electrophysiol       Date:  2020-02-17       Impact factor: 1.976

9.  Comparison of Cryoballoon and Hybrid surgical Posterior Wall Isolation for Persistent Atrial Fibrillation to conventional ablation.

Authors:  Eric Nordsieck; Xin J Zhang; Pankaj Malhotra; Dali Fan; Nayereh G Pezeshkian; Uma N Srivatsa
Journal:  J Atr Fibrillation       Date:  2019-02-28

10.  Thermal Field in Cryoablation Procedures for Pulmonary Veins Isolation: Importance of Esophageal Temperature Monitoring.

Authors:  Antonio Fasano; Luca Anfuso; Giuseppe Arena; Claudio Pandozi
Journal:  J Atr Fibrillation       Date:  2017-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.