Validation of a computer-aided diagnosis system for the automatic identification of carotid atherosclerosis.

Lilla Bonanno1, Silvia Marino2, Placido Bramanti3, Fabrizio Sottile4.   

Abstract

Carotid atherosclerosis represents one of the most important causes of brain stroke. The degree of carotid stenosis is, up to now, considered one of the most important features for determining the risk of brain stroke. Ultrasound (US) is a non-invasive, relatively inexpensive, portable technique, which has an excellent temporal resolution. Computer-aided diagnosis (CAD) has become one of the major research fields in medical and diagnostic imaging. We studied US images of 44 patients, 22 patients with and 22 without carotid artery stenosis, by using US examination and applying a CAD system, an automatic prototype software to detect carotid plaques. We obtained 287 regions: 60 were classified as plaques, with an average signal echogenicity of 244.1 ± 20.0 and 227 were classified as non-plaques, with an average signal echogenicity of 193.8 ± 38.6 compared with the opinion of an expert neurologist (golden test). The receiver operating characteristic (ROC) analysis revealed a highly significant area under the ROC curve difference from 0.5 (null hypothesis) in the discrimination between plaques and non-plaques; the diagnostic accuracy was 89% (95% CI: 0.85-0.92), with an appropriate cut-off value of 236.8, sensitivity was 83% and specificity reached a value of 85%. The experimental results showed that the proposed method is feasible and has a good agreement with the expert neurologist. Without the need of any user-interaction, this method generates a detection out-put that may be useful in second opinion.
Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CAD system; Carotid atherosclerosis; Ultrasound image; Watershed segmentation

Mesh:

Year:  2014        PMID: 25444691     DOI: 10.1016/j.ultrasmedbio.2014.09.004

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  1 in total

1.  A Computer-Aided Diagnosis System for Measuring Carotid Artery Intima-Media Thickness (IMT) Using Quaternion Vectors.

Authors:  Uğurhan Kutbay; Fırat Hardalaç; Mehmet Akbulut; Ünsal Akaslan; Selami Serhatlıoğlu
Journal:  J Med Syst       Date:  2016-05-02       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.