Literature DB >> 25444250

High throughput quantification of prohibited substances in plasma using thin film solid phase microextraction.

Nathaly Reyes-Garcés1, Barbara Bojko1, Janusz Pawliszyn2.   

Abstract

Simple, fast and efficient sample preparation approaches that allow high-throughput isolation of various compounds from complex matrices are highly desired in bioanalysis. Particularly sought are methods that can, without sacrificing time, easily remove matrix interferences capable of inducing ionization suppression/enhancement, or causing detrimental effects in instrumental performance. In this work, an automated high-throughput sample preparation method using thin film solid phase microextraction (SPME) for the analysis of multiple prohibited substances in plasma is proposed. A biocompatible SPME extraction phase made of hydrophilic-lipophilic balance particles immobilized with polyacrylonitrile (PAN) demonstrated satisfactory extraction capabilities for 25 compounds of a wide range of polarities (logP from -2 to 6.8). Due to the well-known biocompatible characteristics of PAN-based SPME coatings, minimum sample handling was required. Experimental conditions for pre-conditioning, extraction, wash and desorption were carefully optimized for the proposed method. By taking full advantage of the 96 thin film handling capability of the automated system, a preparation time of approximately 1.5min per sample can be achieved. Satisfactory results in terms of absolute matrix effects were found for the majority of the studied analytes, given that 24 out of 25 compounds exhibited values in the range of 100 and 120%. The method was validated in terms of linearity (R(2)>0.99), inter and intra-day accuracy (85-130%) and precision (<20%) and limits of quantitation (0.25-10ngmL(-1) for most compounds).
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  High throughput; Plasma; Prohibited substances; Sample preparation; Solid phase microextraction; Thin film

Mesh:

Year:  2014        PMID: 25444250     DOI: 10.1016/j.chroma.2014.11.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Quantitative analysis of biofluid spots by coated blade spray mass spectrometry, a new approach to rapid screening.

Authors:  Germán Augusto Gómez-Ríos; Marcos Tascon; Nathaly Reyes-Garcés; Ezel Boyacı; Justen Poole; Janusz Pawliszyn
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379

2.  Matrix compatibility of typical sol-gel solid-phase microextraction coatings in undiluted plasma and whole blood for the analysis of phthalic acid esters.

Authors:  Xiao-Wei Zhang; Yao-Juan Chu; Yu-Hao Li; Xiu-Juan Li
Journal:  Anal Bioanal Chem       Date:  2022-02-16       Impact factor: 4.142

3.  Modifying current thin-film microextraction (TFME) solutions for analyzing prohibited substances: Evaluating new coatings using liquid chromatography.

Authors:  Łukasz Sobczak; Dominika Kołodziej; Krzysztof Goryński
Journal:  J Pharm Anal       Date:  2022-01-04

4.  High-throughput analysis using non-depletive SPME: challenges and applications to the determination of free and total concentrations in small sample volumes.

Authors:  Ezel Boyacı; Barbara Bojko; Nathaly Reyes-Garcés; Justen J Poole; Germán Augusto Gómez-Ríos; Alexandre Teixeira; Beate Nicol; Janusz Pawliszyn
Journal:  Sci Rep       Date:  2018-01-18       Impact factor: 4.379

5.  Polyamide Noncoated Device for Adsorption-Based Microextraction and Novel 3D Printed Thin-Film Microextraction Supports.

Authors:  Dominika Kołodziej; Łukasz Sobczak; Krzysztof Goryński
Journal:  Anal Chem       Date:  2022-02-03       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.