Literature DB >> 25442519

Nafion covered lead film electrode for the voltammetric determination of caffeine in beverage samples and pharmaceutical formulations.

Katarzyna Tyszczuk-Rotko1, Ilona Bęczkowska2.   

Abstract

This paper presents a sensitive, selective and low-cost voltammetric method for the determination of caffeine using a Nafion covered lead film electrode. The sensor was prepared on a glassy carbon electrode modified with lead film recovered by a Nafion layer. Caffeine was accumulated and then oxidised at the modified electrode surface to produce two anodic peaks at 0.86 and 1.40 V (vs. Ag/AgCl) in 0.1 mol L(-1) H2SO4 medium. The obtained detection limits for caffeine following 120 s of accumulation time were equal to 1.7 × 10(-8) mol L(-1) (for peak 1) and 2.2 × 10(-7) mol L(-1) (for peak 2). The method was successfully applied to determination of caffeine in tea, coffee, soft and energy drink samples as well as pharmaceutical formulation and the contents closely corresponded to those quoted by the manufacturer and those obtained by the reported spectrophotometric method.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adsorptive stripping voltammetry; Caffeine; Lead film electrode; Nafion film

Mesh:

Substances:

Year:  2014        PMID: 25442519     DOI: 10.1016/j.foodchem.2014.09.056

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

1.  Synthesis and Characterization of Polypyrrole Film Doped with Both Molybdate and Salicylate and Its Application in the Corrosion Protection for Low Carbon Steel.

Authors:  Vu Quoc Trung; Ha Manh Hung; Le Van Khoe; Le Minh Duc; Nguyen Thi Bich Viet; Duong Khanh Linh; Vu Thi Huong; Nguyen Dang Dat; Doan Thi Yen Oanh; Ngo Xuan Luong; Nguyen Thuy Chinh; Hoang Thai; Hoang Thi Tuyet Lan; Cao Long Van; Ştefan Ţălu; Dung Nguyen Trong
Journal:  ACS Omega       Date:  2022-06-03

2.  Improved Voltammetric Determination of Kynurenine at the Nafion Covered Glassy Carbon Electrode - Application in Samples Delivered from Human Cancer Cells.

Authors:  Ilona Sadok; Katarzyna Tyszczuk-Rotko; Robert Mroczka; Jędrzej Kozak; Magdalena Staniszewska
Journal:  Int J Tryptophan Res       Date:  2021-06-30

3.  Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages.

Authors:  Luca Redivo; Miroslav Stredanský; Elisabetta De Angelis; Luciano Navarini; Marina Resmini; Ĺubomír Švorc
Journal:  R Soc Open Sci       Date:  2018-05-02       Impact factor: 2.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.