Literature DB >> 25442043

Impact of intrafraction and residual interfraction effect on prostate proton pencil beam scanning.

Shikui Tang1, Curtiland Deville2, Zelig Tochner2, Ken Kang-Hsin Wang3, James McDonough2, Neha Vapiwala2, Stefan Both2.   

Abstract

PURPOSE: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. METHODS AND MATERIALS: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the "true" dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect.
RESULTS: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D99 (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D99 was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant.
CONCLUSIONS: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2014        PMID: 25442043     DOI: 10.1016/j.ijrobp.2014.08.015

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy.

Authors:  Mingyao Zhu; Adeel Kaiser; Mark V Mishra; Young Kwok; Jill Remick; Cristina DeCesaris; Katja M Langen
Journal:  Adv Radiat Oncol       Date:  2019-12-26

2.  Prostate Cancer Treatment with Pencil Beam Proton Therapy Using Rectal Spacers sans Endorectal Balloons.

Authors:  Matthew Forsthoefel; Ryan Hankins; Elizabeth Ballew; Cara Frame; David DeBlois; Dalong Pang; Pranay Krishnan; Keith Unger; Keith Kowalczyk; John Lynch; Anatoly Dritschilo; Sean P Collins; Jonathan W Lischalk
Journal:  Int J Part Ther       Date:  2022-04-06

3.  Using CBCT for pretreatment range check in proton therapy: a phantom study for prostate treatment by anterior-posterior beam.

Authors:  El Hassane Bentefour; Stefan Both; Shikui Tang; Hsiao-Ming Lu
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

4.  Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques.

Authors:  Zhong Su; Roelf Slopsema; Stella Flampouri; Zuofeng Li
Journal:  J Appl Clin Med Phys       Date:  2019-09-03       Impact factor: 2.102

Review 5.  Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Authors:  Julia M Pakela; Antje Knopf; Lei Dong; Antoni Rucinski; Wei Zou
Journal:  Front Oncol       Date:  2022-03-09       Impact factor: 6.244

Review 6.  Proton therapy- the modality of choice for future radiation therapy management of Prostate Cancer?

Authors:  Sophie Mangan; Michelle Leech
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2019-10-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.