Literature DB >> 25441879

Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry.

Sudkate Chaiyo1, Orawon Chailapakul2, Weena Siangproh3.   

Abstract

A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection-anodic stripping voltammetry (SI-ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at -1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 μL s(-1). An anodic stripping voltammogram was recorded from -0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at -0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1-30.0 ng mL(-1) and 5.0-60.0 ng mL(-1)). The limit of detection (S/N=3) obtained from the experiment was found to be 0.04 ng mL(-1). The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL(-1), respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Boron-doped diamond thin film electrode (BDD); Copper enhancer; Mercury; Sequential injection–anodic stripping voltammetry (SI–ASV)

Year:  2014        PMID: 25441879     DOI: 10.1016/j.aca.2014.09.011

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Smartphone-based electrochemical analysis integrated with NFC system for the voltammetric detection of heavy metals using a screen-printed graphene electrode.

Authors:  Kingkan Pungjunun; Abdulhadee Yakoh; Sudkate Chaiyo; Weena Siangproh; Narong Praphairaksit; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2022-04-14       Impact factor: 5.833

2.  Cathodically Pretreated AuNPs-BDD Electrode for Detection of Hexavalent Chromium.

Authors:  Yuhao Xu; Chenyu Xiong; Chengyao Gao; Yang Li; Chao Bian; Shanhong Xia
Journal:  Micromachines (Basel)       Date:  2020-12-11       Impact factor: 2.891

  2 in total